Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants

被引:108
作者
Han, CH [1 ]
Johansson, CB [1 ]
Wennerberg, A [1 ]
Albrektsson, T [1 ]
机构
[1] Gothenburg Univ, Inst Surg Sci, Dept Biomat Handicap Res, S-41390 Gothenburg, Sweden
关键词
implant; titanium; blasted biomechanical; histomorphometry;
D O I
10.1034/j.1600-0501.1998.090101.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Screw shaped implants of commercially pure (c.p.) titanium and titanium-6aluminum-4vanadium (Ti6Al4V) were blasted with particles of TiO2 of mean sizes of 25 mu m (Group I) and 75 mu m (Group II) and inserted in rabbit bone for 3 months. The surface roughness of the implants was examined and quantified with an optical scanning 3-dimensional instrument (TopScan 3D system), revealing the two alloy surfaces in each group had similar surface roughness. Biomechanical (removal torque) tests showed the c.p. titanium implants to be significantly more stable in the bone bed than those of Ti6Al4V. In Group I, the c.p titanium implants demonstrated a mean removal torque of 38 N cm while the Ti6Al4V demonstrated a mean removal torque of 27 N cm (P=0.004). Group II implants revealed a mean removal torque of 70 N cm for the c.p. ti and 50 N cm for the alloy samples (P=0.003). The removal torque values were converted to shear forces/strengths by three calculation methods, based on (a) the entire length of the implant surface in the cortical region, (b) the thickness of the cortical bone measured in close vicinity to the thread peaks and (c) the bone-metal contact length measured on the non-unscrewed neighbouring implants. Group I: (a) the c.p. ti implants revealed a mean shear force of 4 vs a mean of 3 N/mm(2) for the alloy samples. Shear strengths based on (b); were 8 for c.p. ti vs 6 N/mm(2) for the alloy. The mean shear strength/force if calculated according to (c) revealed 23 for c.p. ti vs 18 N/mm(2) for the alloy. Corresponding numbers for Group II; (a) c.p. ti 8 compared to 6 N/mm(2) for the alloy, (b) c.p. ti demonstrated a mean value of 17 vs 11 N/mm(2) for the alloy. According to method (c); c.p. ti had a mean shear strength of 26 vs 22 N/mm(2) for the alloy samples. Histomorphometrical comparisons were performed on 10 mu m thick undecalcified ground sections in the light microscope. In both Group I and Group II, the calculations of the mean bone-to-metal contact demonstrated more bone in contact to the c.p. titanium implants than to the Ti6Al4V ones. Whereas comparisons of the bone volume inside the threads demonstrated slightly higher bone volumes around the alloy samples, no statistically significant difference was obtained between the two materials histomorphometrically.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 19 条
[1]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[2]  
CARLSSON L, 1989, THESIS U GOTEBORG GO
[3]  
DEREZENDE MLR, 1993, J MATER SCI-MATER M, V4, P233
[4]  
Donath K., 1988, PRAPARATOR, V34, P197
[5]   Preliminary experimental results on mapping of the elemental distribution of the organic tissues surrounding titanium-alloy implants [J].
Ektessabi, AM ;
Otsuka, T ;
Tsuboi, Y ;
Horino, Y ;
Mokuno, Y ;
Fujii, K ;
Albrektsson, T ;
Sennerby, L ;
Johansson, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 109 :278-283
[6]  
EKTESSABI AM, 1994, INT J PIXE, V4, P81
[7]   CELL-DAMAGE IN-VITRO FOLLOWING DIRECT-CONTACT WITH FINE PARTICLES OF TITANIUM, TITANIUM-ALLOY AND COBALT-CHROME-MOLYBDENUM ALLOY [J].
EVANS, EJ .
BIOMATERIALS, 1994, 15 (09) :713-717
[8]   ANCHORAGE OF TIO2-BLASTED, HA-COATED, AND MACHINED IMPLANTS - AN EXPERIMENTAL-STUDY WITH RABBITS [J].
GOTFREDSEN, K ;
WENNERBERG, A ;
JOHANSSON, C ;
SKOVGAARD, LT ;
HJORTINGHANSEN, E .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (10) :1223-1231
[9]  
Gotfredsen K, 1992, Clin Oral Implants Res, V3, P77, DOI 10.1034/j.1600-0501.1992.030205.x
[10]  
Johansson C, 1987, Int J Oral Maxillofac Implants, V2, P69