Mass transport in sub-2-μm high-performance liquid chromatography

被引:14
作者
Wirth, Mary J. [1 ]
机构
[1] Univ Arizona, Dept Chem, Tucson, AZ 85721 USA
关键词
UHPLC; UPLC; ultra-high pressure; HPLC; mass transport; desorption;
D O I
10.1016/j.chroma.2007.02.087
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Ultra-high pressure liquid chromatography enables increased separation speed and efficiency. The quantitative improvement in efficiency is lower than that predicted by theory, and the reasons are not known. In this work, slow mass transport due to analyte desorption from the stationary phase is discussed as a possible contribution to the lower than expected efficiency. Data in the literature for the reversed phase elution of acetophenone, for which particle size was varied with constant particle composition and mobile phase, were used to test this possibility. The mass transport terms for the three particles sizes (1.7, 3.5 and 5.0 mu m) fit well to a model that includes desorption from the stationary phase as a contribution, and this analysis yields an apparent desorption time constant of 2.0(+/- 0.2) ms for acetophenone in a reversed-phase separation. The results indicate that it is reasonable to consider slow desorption as a possible contribution to the reduced plate height for sub-2-mu m particles. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 130
页数:3
相关论文
共 12 条
[1]   Very high pressure HPLC with 1 mm id columns [J].
Colón, LA ;
Cintrón, JM ;
Anspach, JA ;
Fermier, AM ;
Swinney, KA .
ANALYST, 2004, 129 (06) :503-504
[2]   Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1 mm ID columns [J].
de Villiers, A ;
Lauer, H ;
Szucs, R ;
Goodall, S ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1113 (1-2) :84-91
[3]   Evaluation of ultra performance liquid chromatography -: Part I.: Possibilities and limitations [J].
de Villiers, Andre ;
Lestremau, Francois ;
Szucs, Roman ;
Gelebart, Sylvie ;
David, Frank ;
Sandra, Pat .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) :60-69
[4]  
Giddings J.C., 1991, Unified separation science
[5]   The limits of the separation power of unidimensional column liquid chromatography [J].
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1126 (1-2) :6-49
[6]   Linear velocity surge caused by mobile-phase compression as a source of band broadening in isocratic ultrahigh-pressure liquid chromatography [J].
Jerkovich, AD ;
Mellors, JS ;
Thompson, JW ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 2005, 77 (19) :6292-6299
[7]   Ultrahigh pressure reversed-phase capillary liquid chromatography:: Isocratic and gradient elution using columns packed with 1.0-μm particles [J].
MacNair, JE ;
Patel, KD ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :700-708
[8]   Ultrahigh pressure reversed-phase liquid chromatography in packed capillary columns [J].
MacNair, JE ;
Lewis, KC ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :983-989
[9]  
Majors RE, 2003, LC GC N AM, V21, P600
[10]   Use of 1.5-μm porous ethyl-bridged hybrid particles as a stationary-phase support for reversed-phase ultrahigh-pressure liquid chromatography [J].
Mellors, JS ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 2004, 76 (18) :5441-5450