Head registration techniques for image-guided surgery

被引:3
作者
Alp, MS [1 ]
Dujovny, M [1 ]
Misra, M [1 ]
Charbel, FT [1 ]
Ausman, JI [1 ]
机构
[1] Univ Illinois, Dept Neurosurg MC799, Chicago, IL 60612 USA
关键词
frameless stereotaxy; fiducial; image registration; neuronavigation; stereotactic microscope;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Localization of the pathological structures in relation to the surrounding anatomy and understanding of the surgical anatomy are probably the most important keys to successful neurosurgery. Image-guided surgery is an important tool for understanding an individual's anatomy and for precisely locating the lesion. Head registration is the most important step in image-guided surgery, required by every system in use today, although these systems show great differences. In this study, head registration techniques and user algorithms in 83 image-guided surgery cases were analyzed. Several types of fiducials including skin markers, bone fiducials, and the stereotactic frame were used for registration. Clinical applications, ease of use, and computer-calculated accuracy values for each type were compared. The average accuracy was 1.50 mm. X-spot skin markers are the fiducials most commonly used with CT scan. The stereotactic frame was the most accurate method, with an accuracy of 0.69 mm. Disc-shaped fiducials were used when MRI was the imaging modality; they provided an average accuracy of 2.62mm. Head registration is an important part of image-guided surgery; the procedure used for registration should be based on the requirements of each individual case. Our results indicated that the stereotactic frame is the most accurate method of registration; however, skin markers provide reasonable accuracy with significant ease of use and patient comfort.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 17 条
[1]   MODIFIED SOLUTION FOR FILLING MRI COORDINATE INDICATORS FOR THE ZD STEREOTAXIC FRAME [J].
ALP, MS ;
LUER, MS ;
MISRA, M ;
DUJOVNY, M ;
AUSMAN, JI .
NEUROLOGICAL RESEARCH, 1995, 17 (04) :295-296
[2]  
ALP MS, IN PRESS SURG NEUROL
[3]   INTRAOPERATIVE LOCALIZATION USING AN ARMLESS, FRAMELESS STEREOTAXIC WAND - TECHNICAL NOTE [J].
BARNETT, GH ;
KORMOS, DW ;
STEINER, CP ;
WEISENBERGER, J .
JOURNAL OF NEUROSURGERY, 1993, 78 (03) :510-514
[4]   FRAMELESS STEREOTAXY IN CHILDREN [J].
DRAKE, JM ;
PRUDENCIO, J ;
HOLOWKA, S ;
RUTKA, JT ;
HOFFMAN, HJ ;
HUMPHREYS, RP .
PEDIATRIC NEUROSURGERY, 1994, 20 (02) :152-159
[5]   INTERACTIVE IMAGE-GUIDED NEUROSURGERY [J].
GALLOWAY, RL ;
MACIUNAS, RJ ;
EDWARDS, CA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (12) :1226-1231
[6]  
GLEASON PL, 1994, STEREOT FUNCT NEUROS, V63, P139, DOI 10.1159/000100305
[7]   CLINICAL USE OF A FRAMELESS STEREOTAXIC ARM - RESULTS OF 325 CASES [J].
GOLFINOS, JG ;
FITZPATRICK, BC ;
SMITH, LR ;
SPETZLER, RF .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :197-205
[8]   STEREOTAXIC LOCALIZATION AND GUIDANCE USING A MACHINE VISION TECHNIQUE [J].
HEILBRUN, MP ;
MCDONALD, P ;
WIKER, C ;
KOEHLER, S ;
PETERS, W .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1992, 58 (1-4) :94-98
[9]   AN ACCURATE AND ERGONOMIC METHOD OF REGISTRATION FOR IMAGE-GUIDED NEUROSURGERY [J].
HENDERSON, JM ;
SMITH, KR ;
BUCHOLZ, RD .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1994, 18 (04) :273-277
[10]   ACCURATE FRAMELESS REGISTRATION OF MR AND CT IMAGES OF THE HEAD - APPLICATIONS IN PLANNING SURGERY AND RADIATION-THERAPY [J].
HILL, DLG ;
HAWKES, DJ ;
GLEESON, MJ ;
COX, TCS ;
STRONG, AJ ;
WONG, WL ;
RUFF, CF ;
KITCHEN, ND ;
THOMAS, DGT ;
SOFAT, A ;
CROSSMAN, JE ;
STUDHOLME, C ;
GANDHE, AJ ;
GREEN, SEM ;
ROBINSON, GP .
RADIOLOGY, 1994, 191 (02) :447-454