Nanoliter-volume proton nuclear magnetic resonance (NMR) spectroscopy is used to monitor the electrolyte temperature during capillary electrophoresis (CE). By measuring the shift in the proton resonance frequency of the water signal, the intracapillary temperature can be recorded noninvasively with subsecond temporal resolution and spatial resolution on the order of 1 mm. Thermal changes of more than 65 degrees C are observed under both equilibrium and nonequilibrium conditions for typical CE separation conditions. Several capillary and buffer combinations are examined with external cooling by both liquid and air convection. Additionally, NMR thermometry allows nonequilibrium temperatures in analyte bands to be monitored during a separation. As one example, a plug of 1 mM NaCl is injected into a capillary filled with 50 mM berate buffer. Upon reaching the NMR detector, the temperature in the NaCl band is more than 20 degrees C higher than the temperature in the surrounding buffer. Such observations have direct applicability to a variety of studies, including experiments which utilize sample stacking and isotachophoresis.
引用
收藏
页码:4991 / 4998
页数:8
相关论文
共 54 条
[31]   High-resolution microcoil NMR for analysis of mass-limited, nanoliter samples [J].
Olson, DL ;
Lacey, ME ;
Sweedler, JV .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :645-650
[32]   HIGH-RESOLUTION MICROCOIL H-1-NMR FOR MASS-LIMITED, NANOLITER-VOLUME SAMPLES [J].
OLSON, DL ;
PECK, TL ;
WEBB, AG ;
MAGIN, RL ;
SWEEDLER, JV .
SCIENCE, 1995, 270 (5244) :1967-1970
[33]   On-flow identification of metabolites of paracetamol from human urine using directly coupled CZE-NMR and CEC-NMR spectroscopy [J].
Pusecker, K ;
Schewitz, J ;
Gfrorer, P ;
Tseng, LH ;
Albert, K ;
Bayer, E ;
Wilson, ID ;
Bailey, NJ ;
Scarfe, GB ;
Nicholson, JK ;
Lindon, JC .
ANALYTICAL COMMUNICATIONS, 1998, 35 (07) :213-215
[34]   On line coupling of capillary electrochromatography, capillary electrophoresis, and capillary HPLC with nuclear magnetic resonance spectroscopy [J].
Pusecker, K ;
Schewitz, J ;
Gfrörer, P ;
Tseng, LH ;
Albert, K ;
Bayer, E .
ANALYTICAL CHEMISTRY, 1998, 70 (15) :3280-3285
[35]   An aluminum heat sink and radiator for electrophoresis capillaries [J].
Rapp, TL ;
Morris, MD .
ANALYTICAL CHEMISTRY, 1996, 68 (24) :4446-4450
[36]  
Rochu D, 1999, ELECTROPHORESIS, V20, P1586, DOI 10.1002/(SICI)1522-2683(19990601)20:7<1586::AID-ELPS1586>3.0.CO
[37]  
2-3
[38]   INFLUENCE OF COLUMN TEMPERATURE ON THE ELECTROPHORETIC BEHAVIOR OF MYOGLOBIN AND ALPHA-LACTALBUMIN IN HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
RUSH, RS ;
COHEN, AS ;
KARGER, BL .
ANALYTICAL CHEMISTRY, 1991, 63 (14) :1346-1350
[39]  
Schell J, 1999, ELECTROPHORESIS, V20, P2864, DOI 10.1002/(SICI)1522-2683(19991001)20:14<2864::AID-ELPS2864>3.0.CO
[40]  
2-9