Performance of selective and partially selective sensors in the recognition of beverages

被引:37
作者
Ciosek, Patrycja [1 ]
Wroblewski, Wojciech [1 ]
机构
[1] Warsaw Univ Technol, Dept Analyt Chem, PL-00664 Warsaw, Poland
关键词
electronic tongue; sensor array; selective sensors; partially selective sensors;
D O I
10.1016/j.talanta.2006.05.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensor array composed of selective and partially selective electrodes is applied to the recognition of beverages: milk, orange juice, and beer. The role of selective and partially selective sensors in classification results is discussed. For this reason two experiments are realized: distinguishing among various types of foodstuffs and the recognition of their origin (manufacturer). In both cases, the measurements were performed in stationary and flow mode. Classical ion-selective electrodes and miniaturized solid-state electrodes were considered. The best results are obtained when the two types of sensor are incorporated in the array, which leads to the highest correctness of the system response. It is however worth to notice, that in the case of some samples (for example, milk) satisfactory results were obtained when only selective or when only partially selective electrodes were applied. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:738 / 746
页数:9
相关论文
共 27 条
[1]   Multi-ion analysis based on versatile sensor head [J].
Chudy, M ;
Wróblewski, W ;
Dybko, A ;
Brzózka, Z .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :320-325
[2]   Novel head for testing and measurement of chemical microsensors [J].
Chudy, M ;
Dybko, A ;
Wróblewski, W ;
Brzózka, Z .
ANALYTICA CHIMICA ACTA, 2001, 429 (02) :347-355
[3]   ISE-based sensor array system for classification of foodstuffs [J].
Ciosek, P ;
Sobanski, T ;
Augustyniak, E ;
Wróblewski, W .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (01) :6-11
[4]   The analysis of sensor array data with various pattern recognition techniques [J].
Ciosek, P ;
Wróblewski, W .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :85-93
[5]   Polymeric membrane ion-selective and cross-sensitive electrode-based electronic tongue for qualitative analysis of beverages [J].
Ciosek, P ;
Augustyniak, E ;
Wróblewski, W .
ANALYST, 2004, 129 (07) :639-644
[6]  
CIOSEK P, IN PRESS TALANTA
[7]   Application of a combined artificial olfaction and taste system to the quantification of relevant compounds in red wine [J].
Di Natale, C ;
Paolesse, R ;
Macagnano, A ;
Mantini, A ;
D'Amico, A ;
Ubigli, M ;
Legin, A ;
Lvova, L ;
Rudnitskaya, A ;
Vlasov, Y .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :342-347
[8]   Miniaturized back-side contact transducer for potentiometric sensors [J].
Dybko, A ;
Zachara, J ;
Golimowski, J ;
Wróblewski, W .
ANALYTICA CHIMICA ACTA, 2003, 485 (01) :103-109
[9]  
DYBKO A, 2001, METROLOGY MEASURING, V8, P263
[10]  
Erdosy M, 2002, ELECTROANAL, V14, P1433, DOI 10.1002/1521-4109(200211)14:19/20<1433::AID-ELAN1433>3.0.CO