A novel head for measurement of chemical sensors was designed and tested. The head was manufactured in the form of a round module allowing simultaneous measurement of 10 sensors. Low cost materials were used for fabrication of a special reference electrode, the head, and plugs connecting the sensors with an electronic amplifier. The hydrodynamic properties of the head such as air bubble distribution, possibility of de-aeration and flow-rate optimisation were investigated. Ks-selective CHEMFETs based on plasticised poly(vinyl chloride) membranes and valinomycine were chosen as model sensors in order to verify the usefulness of the head. The measurements were carried out in a fully computerised flow set-up governed by special software developed under LabView. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:347 / 355
页数:9
相关论文
共 15 条
[1]  
BRZOZKA Z, 1992, P EUR 6
[2]   CHEMICALLY MODIFIED ION-SENSITIVE FIELD-EFFECT TRANSISTORS - ELIMINATION OF THE LIQUID JUNCTION POTENTIAL IN A DOUBLE SENSOR FLOW-INJECTION ANALYSIS CELL [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
SCHOUWENAAR, R ;
BRZOZKA, Z ;
BOS, M ;
BERGVELD, P ;
REINHOUDT, DN .
ANALYTICA CHIMICA ACTA, 1993, 276 (02) :347-352
[3]   CHEMICALLY MODIFIED ION-SENSITIVE FIELD-EFFECT TRANSISTORS - APPLICATION IN FLOW-INJECTION ANALYSIS CELLS WITHOUT POLYMERIC ENCAPSULATION AND WIRE BONDING [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
SUDHOLTER, EJR ;
BERGVELD, P ;
REINHOUDT, DN .
ANALYTICA CHIMICA ACTA, 1991, 248 (02) :307-313
[4]  
DYBKO A, 1999, Patent No. 333615
[5]   Integrated microanalytical system with electrochemical detection [J].
Hoffmann, W ;
Rapp, R .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :471-475
[6]   Continuous-flow system for on line water monitoring using back side contact ISFET-based sensors [J].
Jimenez, C ;
Marques, I ;
Bartroli, J .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3801-3807
[7]  
JUNNING C, 1997, SENSOR MATER, V9, P163
[8]   Determination of ion-selective electrode characteristics by non-linear curve fitting [J].
Kane, P ;
Diamond, D .
TALANTA, 1997, 44 (10) :1847-1858
[9]   MINIATURIZED TOTAL CHEMICAL-ANALYSIS SYSTEMS - A NOVEL CONCEPT FOR CHEMICAL SENSING [J].
MANZ, A ;
GRABER, N ;
WIDMER, HM .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :244-248
[10]   SELECTIVITY COEFFICIENTS FOR ION-SELECTIVE ELECTRODES - RECOMMENDED METHODS FOR REPORTING K-A,B(POT) VALUES - (TECHNICAL REPORT) [J].
UMEZAWA, Y ;
UMEZAWA, K ;
SATO, H .
PURE AND APPLIED CHEMISTRY, 1995, 67 (03) :507-518