Solid phase extraction of food contaminants using molecular imprinted polymers

被引:222
作者
Baggiani, Claudio [1 ]
Anfossi, Laura [1 ]
Giovannoli, Cristina [1 ]
机构
[1] Univ Turin, Dipartimento Chim Analit, Lab Bioanalyt Chem, I-10125 Turin, Italy
关键词
molecular imprinting; solid phase extraction; food analysis; contaminants; pesticides; drugs; antibiotics; mycotoxins;
D O I
10.1016/j.aca.2007.01.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Food contamination from natural or anthropogenic sources poses severe risks to human health. It is now largely accepted that continuous exposure to low doses of toxic chemicals can be related to several chronic diseases, including some type of cancer and serious hormonal dysfunctions. Contemporary analytical methods have the sensitivity required for contamination detection and quantification, but direct application of these methods on food samples can be rarely performed. In fact, the matrix introduces severe disturbances, and analysis can be performed only after some clean-up and preconcentration steps. Current sample pre-treatment methods, mostly based on the solid phase extraction technique, are very fast and inexpensive but show a lack of selectivity, while methods based on immunoaffinity extraction are very selective but expensive and not suitable for harsh environments. Thus, inexpensive, rapid and selective clean-up methods, relaying on "intelligent" materials are needed. Recent years have seen a significant increase of the "molecularly imprinted solid phase extraction" (MISPE) technique in the food contaminant analysis. In fact, this technique seems to be particularly suitable for extractive applications where analyte selectivity in the presence of very complex and structured matrices represents the main problem. In this review, several applications of MISPE in food contamination analysis will be discussed, with particular emphasis on the extraction of pesticides, drugs residua, mycotoxins and environmental contaminants. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:29 / 39
页数:11
相关论文
共 93 条
  • [11] Use of molecularly imprinted polymers in the solid-phase extraction of clenbuterol from animal feeds and biological matrices
    Brambilla, G
    Fiori, M
    Rizzo, B
    Crescenzi, V
    Masci, G
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 759 (01): : 27 - 32
  • [12] Selective extraction of antioxidants with molecularly imprinted polymers
    Brüggemann, O
    Visnjevski, A
    Burch, R
    Patel, P
    [J]. ANALYTICA CHIMICA ACTA, 2004, 504 (01) : 81 - 88
  • [13] Recent applications of sample preparation techniques in food analysis
    Buldini, PL
    Ricci, L
    Sharma, JL
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) : 47 - 70
  • [14] Semi-covalent imprinted polymer using propazine methacrylate as template molecule for the clean-up of triazines in soil and vegetable samples
    Cacho, C.
    Turiel, E.
    Martin-Esteban, A.
    Ayala, D.
    Perez-Conde, C.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1114 (02) : 255 - 262
  • [15] Characterisation and quality assessment of binding sites on a propazine-imprinted polymer prepared by precipitation polymerisation
    Cacho, C
    Turiel, E
    Martin-Esteban, A
    Pérez-Conde, C
    Cámara, C
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02): : 347 - 353
  • [16] Clean-up of triazines in vegetable extracts by molecularly-imprinted solid-phase extraction using a propazine-imprinted polymer
    Cacho, C
    Turiel, E
    Martín-Esteban, A
    Pérez-Conde, C
    Cámara, C
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) : 491 - 496
  • [17] Recent advances in the application of mass spectrometry in food-related analysis
    Careri, M
    Bianchi, F
    Corradini, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 970 (1-2) : 3 - 64
  • [18] Synthesis and application of an oxytetracycline imprinted polymer for the solid-phase extraction of tetracycline antibiotics
    Caro, E
    Marcé, RM
    Cormack, PAG
    Sherrington, DC
    Borrull, F
    [J]. ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) : 81 - 86
  • [19] Application of molecularly imprinted polymers to solid-phase extraction of compounds from environmental and biological samples
    Caro, E
    Marcé, RM
    Borrull, F
    Cormack, PAG
    Sherrington, DC
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (02) : 143 - 154
  • [20] Retention mechanism of analytes in the solid-phase extraction process using molecularly imprinted polymers - Application to the extraction of triazines from complex matrices
    Chapuis, F
    Pichon, V
    Lanza, F
    Sellergren, B
    Hennion, MC
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01): : 93 - 101