Analytical approach to heterogeneity correction factor calculation for brachytherapy

被引:17
作者
Daskalov, GM [1 ]
Kirov, AS [1 ]
Williamson, JF [1 ]
机构
[1] Washington Univ, Sch Med, Edward Mallinckrodt Inst Radiol, Radiat Oncol Ctr, St Louis, MO 63110 USA
关键词
brachytherapy; heterogeneities; dose calculations; analytical approach; Cs-137; Ir-192; Yb-169; I-125; Monte Carlo;
D O I
10.1118/1.598254
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In brachytherapy treatment planning, the effects of tissue and applicator heterogeneities are commonly neglected due to lack of accurate, general, and fast three-dimensional (3D) dose-computational algorithms. A novel approach, based on analytical calculation of scattered photon fluxes inside and around a disk-shaped heterogeneity, has been developed for use in the three-dimensional scatter-subtraction algorithm. Specifically, our model predicts the central-ray dose distribution for a collimated photon isotropic source or brachytherapy "minibeam" in the presence of a slab of heterogeneous material. The model accounts for the lateral dimensions, location, composition, density, and thickness of the heterogeneity using precalculated scatter-to-primary ratios (SPRs) for the corresponding homogeneous problem. The model is applicable to the entire brachytherapy energy range (25 to 662 keV) and to a broad range of materials having atomic numbers of 13 to 82, densities of 2.7 g.cm(-3) (Al) to 21.45 g.cm(-3) (Pt) and thicknesses up to I mean free path. For this range of heterogeneous materials, the heterogeneity correction factors (HCFs) vary from 0.09 to 0.75. The model underestimates HCF when multiple scattering prevails and overestimates HCF when absorption dominates. However, the analytic model agrees with Monte Carlo photon transport (MCPT) benchmark calculations within 1.8% to 10% for I-125, Yb-169, Ir-192, and Cs-137 for a wide variety of materials, with the exception of Ag. For I-125 Shielded by Ag, where the mean discrepancy can exceed 25%, the error is due to K-edge characteristic x rays originating within the heterogeneity. The proposed approach provides reductions in CPU time required of 5x10(4)-10(5) and 100 in comparison with direct MCPT simulation and 1D numerical integration, respectively. The limitations of model applicability, as determined by the physical properties of heterogeneity material and accuracy required, are also discussed. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:722 / 735
页数:14
相关论文
共 29 条
[1]  
*AM ASS PHYS MED, 1987, 21 AM I PHYS AM ASS
[2]  
[Anonymous], 1983, QUADPACK
[3]  
Dahlquist G., 1974, NUMERICAL METHODS
[4]  
Das RK, 1997, INT J RADIAT ONCOL, V38, P843, DOI 10.1016/S0360-3016(97)00067-9
[5]  
Gradshteyn I.S., 1980, TABLE INTEGRALS SERI
[6]  
Hubbell J. H., 1995, 5632 NISTIR
[7]   Two-dimensional scatter integration method for brachytherapy dose calculations in 3D geometry [J].
Kirov, AS ;
Williamson, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2119-2135
[8]   TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12) :2015-2036
[9]   Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
MEDICAL PHYSICS, 1996, 23 (06) :911-919
[10]   VOLUME-BASED GEOMETRIC MODELING FOR RADIATION TRANSPORT CALCULATIONS [J].
LI, ZF ;
WILLIAMSON, JF .
MEDICAL PHYSICS, 1992, 19 (03) :667-677