Conventional MRA and contrast-enhanced MRA of extracranial vessel segments

被引:14
作者
Boos, M [1 ]
Scheffler, K [1 ]
Ott, HW [1 ]
Radu, EW [1 ]
Bongartz, G [1 ]
机构
[1] UNIV BASEL,BIOZENTRUM,BASEL,SWITZERLAND
来源
RADIOLOGE | 1997年 / 37卷 / 07期
关键词
magnetic resonance angiography (MRA); contrast-enhanced MRA (CE-MRA); MRA carotids; contrast agent dosage; time-of-flight MRA (TOF MRA);
D O I
10.1007/s001170050249
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The introduction of fast gradient systems allows a reliable visualization of the extracranial carotid vessels by the magnetic resonance angiography (MRA) which meanwhile is implemented into clinical routine. By the mainly applied time-of-flight (TOF) technique, vessels can be imaged without contrast agent (CA). Due to the application of ultra-fast gradient-echo-sequences, the first-pass evaluation of an intravenous bolus-injection of Gadolinium in the carotids from the aortic arch up to the skull base can be performed in less than 30 s. In this study, advantages and disadvantages of both techniques are discussed. For a qualitatively optimal contrast enhanced MRA (CE-MRA) timing parameters like injection delay, flow rate and the adjustment of sequence parameters have to be considered in relation to the fast Venous return from the sinus to the jugular veins. First, the optimal time point of the data acquisition have been determined at a model and with a computer simulation in reference to the presence of CA in the arteries. As a result, 90 % of the contrast contribution is defined by 16 % of the symmetrically acquired central k-space lines. A measuring protocol for clinical use was obtained by a gradual variation of spacial resolution, measuring time and CA-injection parameters and was proved in normal volunteers and patients. An exact determination of the bolus-arrival-time by means of a test-bolus injection was acquired. The best qualitative results were achieved by a double-dose injection at 2 ml/s injection rate. The temporal reserves of ultra-fast sequences should be invested in the improvement of the spatial resolution. To date, further investigations related to the problem of optimal CA-application may improve the potentials of CE-MRA procedures.
引用
收藏
页码:515 / 528
页数:14
相关论文
共 24 条
[1]  
CARRIERO A, 1995, J NEURORADIOLOGY, V22, P103
[2]   THE ROLE OF INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY IN THE EVALUATION OF EXTRACRANIAL CAROTID-ARTERY DISEASE - CAN THE DECISION FOR CAROTID-ARTERY SURGERY BE MADE SOLELY ON THE BASIS OF ITS FINDINGS [J].
CROCKER, EF ;
TUTTON, RH ;
BOWEN, JC .
JOURNAL OF VASCULAR SURGERY, 1986, 4 (02) :157-163
[3]   HIGH-RESOLUTION, MAGNETIZATION-TRANSFER SATURATION, VARIABLE FLIP ANGLE, TIME-OF-FLIGHT MRA IN THE DETECTION OF INTRACRANIAL VASCULAR STENOSES [J].
DAGIRMANJIAN, A ;
ROSS, JS ;
OBUCHOWSKI, N ;
LEWIN, JS ;
TKACH, JA ;
RUGGIERI, PM ;
MASARYK, TJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (05) :700-706
[4]   IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST [J].
EDELMAN, RR ;
AHN, SS ;
CHIEN, D ;
WEI, L ;
GOLDMANN, A ;
MANTELLO, M ;
KRAMER, J ;
KLEEFIELD, J .
RADIOLOGY, 1992, 184 (02) :395-399
[5]   The relative contributions of carotid duplex scanning, magnetic resonance angiography, and cerebral arteriography to clinical decisionmaking: A prospective study in patients with carotid occlusive disease [J].
Erdoes, LS ;
Marek, JM ;
Mills, JL ;
Berman, SS ;
Whitehill, T ;
Hunter, GC ;
Feinberg, W ;
Krupski, W .
JOURNAL OF VASCULAR SURGERY, 1996, 23 (05) :950-956
[6]  
HEID O, 1997, OUTER LIMITS CONTRAS, V1, P254
[7]   PERIOPERATIVE IMAGING STRATEGIES FOR CAROTID ENDARTERECTOMY - AN ANALYSIS OF MORBIDITY AND COST-EFFECTIVENESS IN SYMPTOMATIC PATIENTS [J].
KENT, KC ;
KUNTZ, KM ;
PATEL, MR ;
KIM, D ;
KLUFAS, RA ;
WHITTEMORE, AD ;
POLAK, JF ;
SKILLMAN, JJ ;
EDELMAN, RR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (11) :888-893
[8]  
KOROSEC FR, 1996, TIME RESOLVED CONTRA, V1, P238
[9]   Noise in MRI [J].
Macovski, A .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :494-497
[10]  
NEUFANG KFR, 1985, EUR J RADIOL, V5, P139