Non-invasive glucose sensing in scattering media using OCT, PAS and TOF techniques

被引:24
作者
Alarousu, E [1 ]
Hast, J [1 ]
Kinnunen, M [1 ]
Kirillin, M [1 ]
Myllylä, R [1 ]
Plucinski, J [1 ]
Popov, A [1 ]
Priezzhev, A [1 ]
Prykäri, T [1 ]
Saarela, J [1 ]
Zuomin, Z [1 ]
机构
[1] Univ Oulu, Optoelect & Measurement Tech Lab, Infotech Oulu, Oulu 90014, Finland
来源
SARATOV FALL MEETING 2003: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE V | 2004年 / 5474卷
关键词
glucose sensing; scattering media; OCT; TOF; PAS;
D O I
10.1117/12.578321
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this paper, optical measurement techniques, which enable non-invasive measurement, are superimposed to glucose sensing in scattering media. Used measurement techniques are Optical Coherence Tomography (OCT), Photoacoustic spectroscopy (PAS) and laser pulse Time-of-Flight (TOF) measurement using a streak camera. In parallel with measurements, a Monte-Carlo (MC) simulation models have been developed. Experimental in vitro measurements were performed using Intralipid(TM) fat emulsion as a tissue simulating phantom for OCT and TOF measurements. In PAS measurements, a pork meat was used as a subject but also preliminary in vivo measurements were done. OCT measurement results show that the slope of the OCT signal's envelope changes as a function of glucose content in the scattering media. TOF measurements show that the laser pulse full width of half maximum (FWHM) changes a little as function of glucose content. An agreement with MC-simulations and measurements with Intralipid(TM) was also found. Measurement results of PAS technique show that changes in glucose content in the pork meat tissue can be measured. In vivo measurements with a human volunteer show that other factors such as physiological change, blood circulation and body temperature drift may interfere the PA response of glucose.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 10 条
[1]  
ALAROUSU E, 2003, IN PRESS P RUSS FINN
[2]  
Bouma B.E., 2002, Handbook of Optical Coherence Tomography
[3]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
[4]   OPTICAL-PROPERTIES OF INTRALIPID - A PHANTOM MEDIUM FOR LIGHT-PROPAGATION STUDIES [J].
FLOCK, ST ;
JACQUES, SL ;
WILSON, BC ;
STAR, WM ;
VANGEMERT, MJC .
LASERS IN SURGERY AND MEDICINE, 1992, 12 (05) :510-519
[5]   Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors [J].
Heinemann, L ;
Schmelzeisen-Redeker, G .
DIABETOLOGIA, 1998, 41 (07) :848-854
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Potential application of optical coherence tomography for non-invasive monitoring of glucose concentration [J].
Larin, K ;
Larina, I ;
Motamedi, M ;
Gelikonov, V ;
Kuranov, R ;
Esenaliev, R .
OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING, 2001, 4263 :83-90
[8]   Optical glucose sensing in biological fluids:: an overview [J].
McNichols, RJ ;
Coté, GL .
JOURNAL OF BIOMEDICAL OPTICS, 2000, 5 (01) :5-16
[9]   LIGHT-SCATTERING IN INTRALIPID-10-PERCENT IN THE WAVELENGTH RANGE OF 400-1100 NM [J].
VANSTAVEREN, HJ ;
MOES, CJM ;
VANMARLE, J ;
PRAHL, SA ;
VANGEMERT, MJC .
APPLIED OPTICS, 1991, 30 (31) :4507-4514
[10]  
Weast R.C., 1974, HDB CHEM PHYS, pD