A flexible and wearable biosensor for tear glucose measurement

被引:139
作者
Iguchi, Shigehito
Kudo, Hiroyuki
Saito, Takao
Ogawa, Mitsuhiro
Saito, Hirokazu
Otsuka, Kimio
Funakubo, Akio
Mitsubayashi, Kohji
机构
[1] Tokyo Med & Dent Univ, Dept Biomed Devices & Informat, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo 1010062, Japan
[2] Tokai Univ, Grad Sch Engn, Kanagawa 2591292, Japan
[3] Tokyo Denki Univ, Dept Elect & Comp Engn, Saitama, Japan
基金
日本学术振兴会;
关键词
wearable; biosensor; soft-MEMS; non-invasive; measurement; glucose; tear fluid; bioinstrumentation;
D O I
10.1007/s10544-007-9073-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A flexible and wearable amperometoric glucose sensor was fabricated and tested. Also, the sensor was utilized to tear glucose monitoring. The sensor was constructed by immobilizing GOD onto a flexible oxygen electrode (Pt working electrode and Ag/AgCl counter/reference electrode), which was fabricated using "Soft-MEMS" techniques onto a functional polymer membrane. In purpose of bioinstrumentation, adhesive agents were not used for constructing the flexible biosensor. Linear relationship between glucose concentration and output current was obtained in a range of 0.025-1.475 mmol/l, with a correlation coefficient of 0.998. Current dependences on pH and temperature were also evaluated. The current was largest at pH 7.0 and the current increased when temperature increased. This indicates that the output current depends on enzyme activity. Based on the basic characteristics investigation, the glucose sensor was applied to measurement of glucose in tear fluids on an eye site of a Japan white rabbit. The change of tear glucose level induced by oral-administration of glucose was monitored as a current change of the sensor attached on the eye site. In this investigation, the tear glucose level varied from 0.16 to 0.46 mmol/l. Although there was a delay of several tens of minutes towards blood sugar level, it is considered to be possible that non-invasive continuous glucose monitoring can be realized using the flexible biosensor.
引用
收藏
页码:603 / 609
页数:7
相关论文
共 24 条
[1]   A glucose sensing contact lens: A non-invasive technique for continuous physiological glucose monitoring [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
JOURNAL OF FLUORESCENCE, 2003, 13 (05) :371-374
[2]  
Chen R, 1996, J CAPILLARY ELECTROP, V3, P243
[3]   EVALUATION OF A NEW SYSTEM FOR SELF BLOOD-GLUCOSE MONITORING [J].
CLARKE, WL ;
BECKER, DJ ;
COX, D ;
SANTIAGO, JV ;
WHITE, NH ;
BETSCHART, J ;
ECKENRODE, K ;
LEVANDOSKI, LA ;
PRUSINSKI, EA ;
SIMINEIRO, LM ;
SNYDER, AL ;
TIDEMAN, AM ;
YAEGER, T .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1988, 4 (03) :209-214
[4]   A thermophilic apoglucose dehydrogenase as nonconsuming glucose sensor [J].
D'Auria, S ;
Di Cesare, N ;
Gryczynski, Z ;
Gryczynski, I ;
Rossi, M ;
Lakowicz, JR .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2000, 274 (03) :727-731
[5]  
DAUM KM, 1982, INVEST OPHTH VIS SCI, V22, P509
[6]   NONINVASIVE BLOOD-GLUCOSE SENSORS BASED ON NEAR-INFRARED SPECTROSCOPY [J].
HEISE, HM ;
MARBACH, R ;
KOSCHINSKY, T ;
GRIES, FA .
ARTIFICIAL ORGANS, 1994, 18 (06) :439-447
[7]   A wearable oxygen sensor for transcutaneous blood gas monitoring at the conjunctiva [J].
Iguchi, S ;
Mitsubayashi, K ;
Uehara, T ;
Ogawa, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2) :733-737
[8]   Determination of glucose in submicroliter samples by CE-LIF using precolumn or on-column enzymatic reactions [J].
Jin, Z ;
Chen, R ;
Colon, LA .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1326-1331
[9]   A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques [J].
Kudo, Hiroyuki ;
Sawada, Takanori ;
Kazawa, Elito ;
Yoshida, Hiromichi ;
Iwasaki, Yasuhiko ;
Mitsubayashi, Kohji .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (04) :558-562
[10]   EFFECTS OF TEMPERATURE, RELATIVE HUMIDITY, AND MODE OF BREATHING ON CANINE AIRWAY SECRETIONS [J].
MAN, SFP ;
ADAMS, GK ;
PROCTOR, DF .
JOURNAL OF APPLIED PHYSIOLOGY, 1979, 46 (02) :205-210