Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures

被引:289
作者
Souverain, S [1 ]
Rudaz, S [1 ]
Veuthey, JL [1 ]
机构
[1] Univ Geneva, Lab Pharmaceut & Analyt Chem, Sch Pharm, CH-1211 Geneva 4, Switzerland
关键词
matrix effects; methadone; off-line sample preparation; on-line solid-phase extraction;
D O I
10.1016/j.chroma.2004.08.118
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Matrix effect on mass spectrometry response was investigated with commercially available electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI) sources coupled with a single quadruple mass spectrometer. A post-column infusion system was used to observe the MS signal alterations of methadone, selected as the model compound, in plasma. For this purpose, two sample preparation procedures were tested: (1) conventional off-line sample preparations with liquid-liquid extraction (LLE), solid-phase extraction (SPE) and protein precipitation (PP) with perchloric acid (PA) and acetonitrile (ACN) and (2) on-line SPE with two different extraction columns packed with a large particle support (LPS) and with restricted access material (RAM), respectively. Whatever the sample preparation procedures, APCI source appeared to be less liable to matrix effect than ESI source. Among the different off-line sample preparations, LLE was the most efficient extraction procedure. With other techniques, MS signal was affected not only by endogenous material but also by procedure introduced compounds. Moreover, on-line SPE-LC-MS configuration exhibited matrix effects, which depend on the API source and the extraction support. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 44 条
[1]  
Abian J, 1999, J MASS SPECTROM, V34, P157, DOI 10.1002/(SICI)1096-9888(199903)34:3<157::AID-JMS804>3.0.CO
[2]  
2-4
[3]  
Ackermann Bradley L., 2002, Current Topics in Medicinal Chemistry, V2, P53, DOI 10.2174/1568026023394605
[4]  
[Anonymous], CHROMATOGRAPHIA
[5]   Confirmatory analysis of sulfonamide antibacterials in bovine liver and kidney: extraction with hot water and liquid chromatography coupled to a single- or triple-quadrupole mass spectrometer [J].
Bogialli, S ;
Curini, R ;
Di Corcia, A ;
Nazzari, M ;
Sergi, M .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (11) :1146-1156
[6]   A liquid chromatography-mass spectrometry assay for analyzing sulfonamide antibacterials in cattle and fish muscle tissues [J].
Bogialli, S ;
Curini, R ;
Di Corcia, A ;
Nazzari, M ;
Samperi, R .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1798-1804
[7]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[8]  
2-S
[9]   Mechanistic aspects of electrospray ionization [J].
Bruins, AP .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :345-357
[10]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105