Matrix effect in LC-ESI-MS and LC-APCI-MS with off-line and on-line extraction procedures

被引:289
作者
Souverain, S [1 ]
Rudaz, S [1 ]
Veuthey, JL [1 ]
机构
[1] Univ Geneva, Lab Pharmaceut & Analyt Chem, Sch Pharm, CH-1211 Geneva 4, Switzerland
关键词
matrix effects; methadone; off-line sample preparation; on-line solid-phase extraction;
D O I
10.1016/j.chroma.2004.08.118
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Matrix effect on mass spectrometry response was investigated with commercially available electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI) sources coupled with a single quadruple mass spectrometer. A post-column infusion system was used to observe the MS signal alterations of methadone, selected as the model compound, in plasma. For this purpose, two sample preparation procedures were tested: (1) conventional off-line sample preparations with liquid-liquid extraction (LLE), solid-phase extraction (SPE) and protein precipitation (PP) with perchloric acid (PA) and acetonitrile (ACN) and (2) on-line SPE with two different extraction columns packed with a large particle support (LPS) and with restricted access material (RAM), respectively. Whatever the sample preparation procedures, APCI source appeared to be less liable to matrix effect than ESI source. Among the different off-line sample preparations, LLE was the most efficient extraction procedure. With other techniques, MS signal was affected not only by endogenous material but also by procedure introduced compounds. Moreover, on-line SPE-LC-MS configuration exhibited matrix effects, which depend on the API source and the extraction support. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 44 条
[21]   Simultaneous determination of a drug candidate and its metabolite in rat plasma samples using ultrafast monolithic column high-performance liquid chromatography/tandem mass spectrometry [J].
Hsieh, Y ;
Wang, GF ;
Wang, YG ;
Chackalamannil, S ;
Brisson, JM ;
Ng, K ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (10) :944-950
[22]   On the mechanisms by which the charged droplets produced by electrospray lead to gas phase ions [J].
Kebarle, P ;
Peschke, M .
ANALYTICA CHIMICA ACTA, 2000, 406 (01) :11-35
[23]   Mechanistic investigation of ionization suppression in electrospray ionization [J].
King, R ;
Bonfiglio, R ;
Fernandez-Metzler, C ;
Miller-Stein, C ;
Olah, T .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (11) :942-950
[24]   Current developments in LC-MS for pharmaceutical analysis [J].
Lim, CK ;
Lord, G .
BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2002, 25 (05) :547-557
[25]   Liquid chromatography-mass spectrometry:: potential in forensic and clinical toxicology [J].
Marquet, P ;
Lachâtre, G .
JOURNAL OF CHROMATOGRAPHY B, 1999, 733 (1-2) :93-118
[26]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[27]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[28]   Liquid chromatography mass spectrometry in forensic and clinical toxicology [J].
Maurer, HH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (01) :3-25
[29]   Investigation of matrix effects in bioanalytical high-performance liquid chromatography/tandem mass spectrometric assays: application to drug discovery [J].
Mei, H ;
Hsieh, YS ;
Nardo, C ;
Xu, XY ;
Wang, SY ;
Ng, K ;
Korfmacher, WA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (01) :97-103
[30]   Ion suppression effects in liquid chromatography-electrospray-ionisation transport-region collision induced dissociation mass spectrometry with different serum extraction methods for systematic toxicological analysis with mass spectra libraries [J].
Müller, C ;
Schäfer, P ;
Störtzel, M ;
Vogt, S ;
Weinmann, W .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :47-52