Dual-energy contrast-enhanced digital breast tomosynthesis - a feasibility study

被引:58
作者
Carton, A-K [1 ]
Gavenonis, S. C. [1 ]
Currivan, J. A. [1 ]
Conant, E. F. [1 ]
Schnall, M. D. [1 ]
Maidment, A. D. A. [1 ]
机构
[1] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
X-RAY-SPECTRA; SUBTRACTION MAMMOGRAPHY; PERFORMANCE; RESOLUTION; ALGORITHM; FEATURES;
D O I
10.1259/bjr/80279516
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast-enhanced digital breast tomosynthesis (CE-DBT) is a novel modality for imaging breast lesion morphology and vascularity. The purpose of this study is to assess the feasibility of dual-energy subtraction as a technique for CE-DBT (a temporal subtraction CE-DBT technique has been described previously). As CE-DBT evolves, exploration of alternative image acquisition techniques will contribute to its optimisation. Evaluation of dual-energy CE-DBT was conducted with Institutional Review Board (IRB) approval from our institution and in compliance with federal Health Insurance Portability and Accountability Act (HIPAA) guidelines. A 55-year old patient with a known malignancy in the right breast underwent imaging with MRI and CE-DBT. CE-DBT was performed in the medial lateral oblique view with a DBT system, which was modified under IRB approval to allow high-energy image acquisition with a 0.25 mm Cu filter. Image acquisition occurred via both temporal and dual-energy subtraction CE-DBT. Between the pre- and post-contrast DBT image sets, a single bolus of iodinated contrast agent (1.0 ml kg(-1)) was administered, followed by a 60 ml saline flush. The contrast agent and saline were administrated manually at a rate of similar to 2 ml s(-1). Images were reconstructed using filtered-back projection and transmitted to a clinical PACS workstation. Dual-energy CE-DBT was shown to be clinically feasible. In our index case, the dual-energy technique was able to provide morphology and kinetic information about the known malignancy. This information was qualitatively concordant with that of CE-MRI. Compared with the temporal subtraction CE-DBT technique, dual-energy CE-DBT appears less susceptible to motion artefacts.
引用
收藏
页码:344 / 350
页数:7
相关论文
共 29 条
[21]   Diagnostic architectural and dynamic features at breast MR imaging:: Multicenter study [J].
Schnall, MD ;
Blume, J ;
Bluemke, DA ;
DeAngelis, GA ;
DeBruhl, N ;
Harms, S ;
Heywang-Köbrunner, SH ;
Hylton, N ;
Kuhl, CK ;
Pisano, ED ;
Causer, P ;
Schnitt, SJ ;
Thickman, D ;
Stelling, CB ;
Weatherall, PT ;
Lehman, C ;
Gatsonis, CA .
RADIOLOGY, 2006, 238 (01) :42-53
[22]   Development of contrast digital mammography [J].
Skarpathiotakis, M ;
Yaffe, MJ ;
Bloomquist, AK ;
Rico, D ;
Muller, S ;
Rick, A ;
Jeunehomme, F .
MEDICAL PHYSICS, 2002, 29 (10) :2419-2426
[23]  
SPELIC DC, 2007, BIOMED IMAGING INTER, V3
[24]   A search for optimal x-ray spectra in iodine contrast media mammography [J].
Ullman, G ;
Sandborg, M ;
Dance, DR ;
Yaffe, M ;
Carlsson, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (13) :3143-3152
[25]   Quantitative evaluation of noise reduction strategies in dual-energy imaging [J].
Warp, RJ ;
Dobbins, JT .
MEDICAL PHYSICS, 2003, 30 (02) :190-198
[26]   TUMOR ANGIOGENESIS AND METASTASIS - CORRELATION IN INVASIVE BREAST-CARCINOMA [J].
WEIDNER, N ;
SEMPLE, JP ;
WELCH, WR ;
FOLKMAN, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (01) :1-8
[27]   Optimization of exposure parameters in full field digital mammography [J].
Williams, Mark B. ;
Raghunathan, Priya ;
More, Mitali J. ;
Seibert, J. Anthony ;
Kwan, Alexander ;
Lo, Joseph Y. ;
Samei, Ehsan ;
Ranger, Nicole T. ;
Fajardo, Laurie L. ;
McGruder, Allen ;
McGruder, Sandra M. ;
Maidment, Andrew D. A. ;
Yaffe, Martin J. ;
Bloomquist, Aili ;
Mawdsley, Gordon E. .
MEDICAL PHYSICS, 2008, 35 (06) :2414-2423
[28]   A comparison of reconstruction algorithms for breast tomosynthesis [J].
Wu, T ;
Moore, RH ;
Rafferty, EA ;
Kopans, DB .
MEDICAL PHYSICS, 2004, 31 (09) :2636-2647
[29]  
TOTAL VARIATION DENO