Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy

被引:156
作者
Deurloo, KEI
Steenbakkers, RJHM
Zijp, LJ
de Bois, JA
Nowak, PJCM
Rasch, CRN
van Herk, M
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
[2] Erasmus MC Dijkzigt, Dept Radiotherapy, Rotterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 61卷 / 01期
关键词
prostate and seminal vesicles; organ deformation; repeat CT scans; image-guided radiotherapy;
D O I
10.1016/j.ijrobp.2004.09.023
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The prostate is known to translate and rotate under influence of rectal filling changes and many studies have addressed the magnitude of these motions. However, prostate shape variations also have been reported. For image-guided radiotherapy, it is essential to know the relative magnitude of translations, rotations, and shape variation so that the most appropriate correction strategy can be chosen. However, no quantitative analysis of shape variation has been performed. It is, therefore, the purpose of this article to develop a method to determine shape variation of complex organs and apply it to determine shape variation during external beam radiotherapy of a GTV (gross tumor volume) consisting of prostate and seminal vesicles. Methods and Materials: For this study, the data of 19 patients with prostate cancer were used. Each patient received a planning computed tomography (CT) scan and 8-12 (11 on average) repeat CT scans that were made during the course of conformal radiotherapy. One observer delineated the GTV in all scans, and volume variations were measured. After matching the GTVs for each patient for translation and rotation, a coverage probability matrix was constructed and the 50% isosurface was taken to determine the average GTV surface. Perpendicular distances between the average GTV and the individual GTVs were calculated for each point of the average GTV, and their variation was expressed in terms of local standard deviation (SD). The local SDs of the shape variation of all 19 patients were mapped onto a reference case by matching and morphing of the individual average GTVs. Repeated delineation of the GTV was done for 6 patients to determine intraobserver variation. Finally, the measured shape variation was corrected for intraobserver variation to estimate the "real" shape variation. Results: No significant variations in GTV volume were observed. The measured shape variation (including delineation variation) was largest at the tip of the vesicles (SD = 2.0 mm), smallest at the left and right side of the prostate (SD = 1.0 mm), and average elsewhere (SD = 1.5 mm). At the left, right, and cranial sides of the prostate, the intraobserver variation was of the same order of magnitude as the measured shape variation; elsewhere it was smaller. However, the accuracy of the estimated SD for intraobserver variation was about half of the accuracy of the estimated SD for the measured shape variation, giving an overall uncertainty of maximum 0.6 mm SD in the estimate of the "real" shape variation. The "real" shape variation was small at the left, right, and cranial side of the prostate (SD <0.5 mm) and between 0.5 mm and 1.6 mm elsewhere. Conclusions: We developed a method to quantify shape variation of organs with a complex shape and applied it to a GTV consisting of prostate and seminal vesicles. Deformation of prostate and seminal vesicles during the course of radiotherapy is small (relative to organ motion). Therefore, it is a valid approximation in image-guided radiotherapy of prostate cancer, in first order, to correct only for setup errors and organ motion. Prostate and seminal vesicles deformation can be considered as a second-order effect. (C) 2005 Elsevier Inc.
引用
收藏
页码:228 / 238
页数:11
相关论文
共 35 条
[1]   Prostate target volume variations during a course of radiotherapy [J].
Antolak, JA ;
Rosen, II ;
Childress, CH ;
Zagars, GK ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :661-672
[2]   MEASUREMENT OF PROSTATE MOVEMENT OVER THE COURSE OF ROUTINE RADIOTHERAPY USING IMPLANTED MARKERS [J].
BALTER, JM ;
SANDLER, HM ;
LAM, K ;
BREE, RL ;
LICHTER, AS ;
TENHAKEN, RK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :113-118
[3]   Analysis of prostate and seminal vesicle motion: Implications for treatment planning [J].
Beard, CJ ;
Kijewski, P ;
Bussiere, M ;
Gelman, R ;
Gladstone, D ;
Shaffer, K ;
Plunkett, M ;
Costello, P ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (02) :451-458
[4]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[5]   Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging [J].
Bharatha, A ;
Hirose, M ;
Hata, N ;
Warfield, SK ;
Ferrant, M ;
Zou, KH ;
Suarez-Santana, E ;
Ruiz-Alzola, J ;
D'Amico, A ;
Cormack, RA ;
Kikinis, R ;
Jolesz, FA ;
Tempany, CMC .
MEDICAL PHYSICS, 2001, 28 (12) :2551-2560
[6]  
DeCarlo D, 1996, PROC GRAPH INTERF, P194
[7]   Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning [J].
Fiorino, C ;
Reni, M ;
Bolognesi, A ;
Cattaneo, GM ;
Calandrino, R .
RADIOTHERAPY AND ONCOLOGY, 1998, 47 (03) :285-292
[8]  
Ghilezan M., 2002, International Journal of Radiation Oncology Biology Physics, V54, P182, DOI 10.1016/S0360-3016(02)03373-4
[9]   Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate [J].
Hanley, J ;
Lumley, MA ;
Mageras, GS ;
Sun, J ;
Zelefsky, MJ ;
Leibel, SA ;
Fuks, Z ;
Kutcher, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (02) :435-444
[10]  
HOOGEMAN MS, IN PRESS RADIOTHER O