Triglycidylamine crosslinking of porcine aortic valve cusps or bovine pericardium results in improved biocompatibility, biomechanics, and calcification resistance - Chemical and biological mechanisms

被引:74
作者
Connolly, JM
Alferiev, I
Clark-Gruel, JN
Eidelman, N
Sacks, M
Palmatory, E
Kronsteiner, A
DeFelice, S
Xu, J
Ohri, R
Narula, N
Vyavahare, N
Levy, RJ
机构
[1] Childrens Hosp Philadelphia, Div Cardiol, Abramson Res Ctr 702, Philadelphia, PA 19104 USA
[2] NIST, Amer Dent Assoc Hlth Fdn, Paffenbarger Res Ctr, Gaithersburg, MD 20899 USA
[3] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[4] Univ Penn, Sch Med, Dept Pathol, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/S0002-9440(10)62227-4
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
We investigated a novel polyepoxide crosslinker that was hypothesized to confer both material stabilization and calcification resistance when used to prepare bioprosthetic heart valves. Triglycidylamine (TGA) was synthesized via reacting epichlorhydrin and NH3. TGA was used to crosslink porcine aortic cusps, bovine pericardium, and type I collagen. Control materials were crosslinked with glutaraldehyde (Glut). TGA-pretreated materials had shrink temperatures comparable to Glut fixation. However, TGA crosslinking conferred significantly greater collagenase resistance than Glut pretreatment, and significantly improved biomechanical compliance. Sheep aortic valve interstitial cells grown on TGA-pretreated collagen did not calcify, whereas sheep aortic valve interstitial cells grown on control substrates calcified extensively. Rat subdermal implants (porcine aortic cusps/ bovine pericardium) pretreated with TGA demonstrated significantly less calcification than Glut pretreated implants. Investigations of extracellular matrix proteins associated with calcification, matrix metalloproteinases (MMPs) 2 and 9, tenascin-C, and osteopontin, revealed that MMP-9 and tenascin-C demonstrated reduced expression both in vitro and in vivo with TGA crosslinking compared to controls, whereas osteopontin and MMP-2 expression were not affected. TGA pretreatment of heterograft biomaterials results in improved stability compared to Glut, confers biomechanical properties superior to Glut crosslinking, and demonstrates significant calcification resistance.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 38 条
[1]   High reactivity of alkyl sulfides towards epoxides under conditions of collagen fixation - a convenient approach to 2-amino-4-butyrolactones [J].
Alferiev, IS ;
Hinson, JT ;
Ogle, M ;
Breuer, E ;
Levy, RJ .
BIOMATERIALS, 2001, 22 (18) :2501-2506
[2]  
BERNACCA GM, 1992, BIOMATERIALS, V13, P345
[3]  
Beshensky AM, 2001, J AM SOC NEPHROL, V12, P2108, DOI 10.1681/ASN.V12102108
[4]   Elastase and matrix metalloproteinase inhibitors induce regression, and tenascin-C antisense prevents progression, of vascular disease [J].
Cowan, KN ;
Jones, PL ;
Rabinovitch, M .
JOURNAL OF CLINICAL INVESTIGATION, 2000, 105 (01) :21-34
[5]   Regression of hypertrophied rat pulmonary arteries in organ culture is associated with suppression of proteolytic activity, inhibition of tenascin-C, and smooth muscle cell apoptosis [J].
Cowan, KN ;
Jones, PL ;
Rabinovitch, M .
CIRCULATION RESEARCH, 1999, 84 (10) :1223-1233
[6]   Proteolysis of latent transforming growth factor-β (TGF-β)-binding protein-1 by osteoclasts -: A cellular mechanism for release of TGF-β from bone matrix [J].
Dallas, SL ;
Rosser, JL ;
Mundy, GR ;
Bonewald, LF .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2002, 277 (24) :21352-21360
[7]   EFFECTS OF GLUTARALDEHYDE ON EXPERIMENTAL ARTERIAL ISOGRAFTS AND ALLOGRAFTS IN RATS [J].
DUMONT, CE ;
PLISSONNIER, D ;
GUETTIER, C ;
MICHEL, JB .
JOURNAL OF SURGICAL RESEARCH, 1993, 54 (01) :61-69
[8]   Matrix metalloproteinase expression in nonrheumatic aortic stenosis [J].
Edep, ME ;
Shirani, J ;
Wolf, P ;
Brown, DL .
CARDIOVASCULAR PATHOLOGY, 2000, 9 (05) :281-286
[9]   Characterization of combinatorial polymer blend composition gradients by FTIR microspectroscopy [J].
Eidelman, N ;
Simon, CG .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2004, 109 (02) :219-231
[10]   Effects of mechanical fatigue on the bending properties of the porcine bioprosthetic heart valve [J].
Gloeckner, DC ;
Billiar, KL ;
Sacks, MS .
ASAIO JOURNAL, 1999, 45 (01) :59-63