Multislice computed tomographic coronary angiography: Experience in a UK centre

被引:23
作者
Morgan-Hughes, GJ [1 ]
Marshall, AJ
Roobottom, CA
机构
[1] Plymouth NHS Trust, SW Cardiothorac Ctr, Dept Cardiol, Plymouth PL6 8DH, Devon, England
[2] Plymouth NHS Trust, SW Cardiothorac Ctr, Dept Radiol, Plymouth PL6 8DH, Devon, England
关键词
computed tomography; non-invasive imaging; multislice computed tomography; coronary angiography;
D O I
10.1016/S0009-9260(03)00051-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and midcoronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for "assessability" and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n = 70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n = 70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition. Morgan-Hughes, G. J. et al. (2003). Clinical Radiology 58, 378-383. (C) 2003 The Royal College of Radiologists. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 20 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Non-invasive coronary artery imaging with electron beam computed tomography and magnetic resonance imaging [J].
de Feyter, PJ ;
Nieman, K ;
van Ooijen, P ;
Oudkerk, M .
HEART, 2000, 84 (04) :442-448
[5]  
Flohr T, 2001, AM J CARDIOL, V88, p76E
[6]   Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time:: first experiences [J].
Heuschmid, M ;
Küttner, A ;
Flohr, T ;
Wildberger, JE ;
Lell, M ;
Kopp, AF ;
Schröder, S ;
Baum, U ;
Schaller, S ;
Hartung, A ;
Ohnesorge, B ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (06) :721-724
[7]   Coronary artery calcium: Absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies [J].
Hong, C ;
Becker, CR ;
Schoepf, UJ ;
Ohnesorge, B ;
Bruening, R ;
Reiser, MF .
RADIOLOGY, 2002, 223 (02) :474-480
[8]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[9]   Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses [J].
Knez, A ;
Becker, CR ;
Leber, A ;
Ohnesorge, B ;
Becker, A ;
White, C ;
Haberl, R ;
Reiser, MF ;
Steinbeck, G .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1191-+
[10]   Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Heuschmid, M ;
Georg, C ;
Ohnesorge, B ;
Kuzo, R ;
Claussen, CD .
RADIOLOGY, 2001, 221 (03) :683-688