Beam orientation optimization in intensity-modulated radiation treatment planning

被引:93
作者
Pugachev, AB [1 ]
Boyer, AL [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
inverse planning; treatment planning; beam orientation optimization; backprojection; intensity modulation;
D O I
10.1118/1.599001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Beam direction optimization is an important problem in radiation therapy. In intensity modulated radiation therapy (IMRT), the difficulty for computer optimization of the beam directions arises from the fact that they are coupled with the intensity profiles of the incident beams. In order to obtain the optimal incident beam directions using iterative or stochastic methods, the beam profiles ought to be optimized after every change of beam configuration. In this paper we report an effective algorithm to optimize gantry angles for IMRT. In our calculation the gantry angles and the beam profiles (beamlet weights) were treated as two separate groups of variables. The gantry angles were sampled according to a simulated annealing algorithm. For each sampled beam configuration, beam profile calculation was done using a fast filtered backprojection (FBP) method. Simulated annealing was also used for beam profile optimization to examine the performance of the FBP for beam orientation optimization. Relative importance factors were incorporated into the objective function to control the relative importance of the target and the sensitive structures. Minimization of the objective function resulted in the best possible beam orientations and beam profiles judged by the given objective function. The algorithm was applied to several model problems and the results showed that the approach has potential for IMRT applications. (C) 2000 American Association of Physicists in Medicine. [S0094-2405(00)00806-3].
引用
收藏
页码:1238 / 1245
页数:8
相关论文
共 23 条
[1]  
[Anonymous], 1983, Medical Imaging Systems
[2]   Optimal electron and combined electron and photon therapy in the phase space of complication-free cure [J].
Åsell, M ;
Hyödynmaa, S ;
Söderström, S ;
Brahme, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) :235-252
[3]   OPTIMIZATION OF BEAM ORIENTATIONS IN RADIATION-THERAPY - SOME THEORETICAL CONSIDERATIONS [J].
BORTFELD, T ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02) :291-304
[4]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[5]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[6]   INVERSION OF FAN-BEAM SCANS IN RADIO ASTRONOMY [J].
BRACEWELL, RN ;
RIDDLE, AC .
ASTROPHYSICAL JOURNAL, 1967, 150 (2P1) :427-+
[7]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[8]   Multiple local minima in radiotherapy optimization problems with dose-volume constraints [J].
Deasy, JO .
MEDICAL PHYSICS, 1997, 24 (07) :1157-1161
[9]   Optimization of beam orientation in radiotherapy using planar geometry [J].
Haas, OCL ;
Burnham, KJ ;
Mills, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2179-2193
[10]   A FILTERED BACKPROJECTION DOSE CALCULATION METHOD FOR INVERSE TREATMENT PLANNING [J].
HOLMES, T ;
MACKIE, TR .
MEDICAL PHYSICS, 1994, 21 (02) :303-313