Overestimation of a stenosis in the internal carotid artery by duplex sonography caused by an increase in volume flow

被引:33
作者
van Everdingen, KJ
van der Grond, J
Kappelle, LJ
机构
[1] Univ Utrecht Hosp, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Univ Utrecht Hosp, Dept Neurol, NL-3584 CX Utrecht, Netherlands
关键词
D O I
10.1016/S0741-5214(98)99999-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: The accuracy of duplex sonography in predicting the degree of an internal carotid artery (ICA) stenosis is decreased when a contralateral high-grade stenosis or occlusion is present. The purpose of this study was to determine whether this overestimation of the stenosis by duplex sonography is associated with an increase in volume now through the ipsilateral ICA. Methods: Forty-seven patients (89 vessels) with a symptomatic ICA stenosis or occlusion who underwent duplex sonography, intraarterial digital subtraction angiography, and magnetic resonance angiography flow quantification of the ICAs were evaluated. Results: With the use of peak systolic velocity criteria, duplex overestimated stenoses more frequently (chi(2) : p = 0.03) in vessels with high volume now (= mean volume now in control group + 2 SD (>274 ml/min), 46% overestimation) than in vessels with normal or low volume flow (<274 ml/min, 20% overestimation). A correlation coefficient of 0.75 (p < 0.001) was found between volume flow and peak systolic velocity in the distal ICA, indicating that increased volume flow causes the peak systolic velocity to increase. Compared with volume flow in the control group (mean +/- SD = 198 +/- 38 ml/min), volume flow was increased in vessels with a 0% to 49% stenosis (mean +/- SD = 272 +/- 100 ml/min, p < 0.05) and in vessels with a 50% to 69% stenosis (mean +/- SD = 291 +/- 79 ml/min, p < 0.01) when the contralateral ICA had a 70% to 99% stenosis or occlusion. Conclusions: Increase in volume now through the ICA frequently causes overestimation of stenoses in the ICA. Increased volume flow is frequently found in ICAs with a <70% stenosis that are contralateral to ICAs with a >70% stenosis or an occlusion.
引用
收藏
页码:479 / 485
页数:7
相关论文
共 25 条
[1]   Effect of contralateral severe stenosis or carotid occlusion on duplex criteria of ipsilateral stenoses: Comparative study of various duplex parameters [J].
AbuRahma, AF ;
Richmond, BK ;
Robinson, PA ;
Khan, S ;
Pollack, JA ;
Alberts, S .
JOURNAL OF VASCULAR SURGERY, 1995, 22 (06) :751-762
[2]   Correlation of peak systolic velocity and angiographic measurement of carotid stenosis revisited [J].
Alexandrov, AV ;
Brodie, DS ;
McLean, A ;
Hamilton, P ;
Murphy, J ;
Burns, PN .
STROKE, 1997, 28 (02) :339-342
[3]   Accuracy and precision of time-averaged flow as measured by nontriggered 2D phase-contrast MR angiography, a phantom evaluation [J].
Bakker, CJG ;
Kouwenhoven, M ;
Hartkamp, MJ ;
Hoogeveen, RM ;
Mali, WPTM .
MAGNETIC RESONANCE IMAGING, 1995, 13 (07) :959-965
[4]   Measuring blood flow by nontriggered 2D phase-contrast MR angiography [J].
Bakker, CJG ;
Hartkamp, MJ ;
Mali, WPTM .
MAGNETIC RESONANCE IMAGING, 1996, 14 (06) :609-614
[6]  
BECKETT WW, 1990, AM J NEURORADIOL, V11, P1049
[7]   CORRELATION OF CINE MR VELOCITY-MEASUREMENTS IN THE INTERNAL CAROTID-ARTERY WITH COLLATERAL FLOW IN THE CIRCLE OF WILLIS - PRELIMINARY-STUDY [J].
DAVIS, WL ;
TURSKI, PA ;
GORBATENKO, KG ;
WEBER, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04) :603-609
[8]  
ENZMANN DR, 1994, AM J NEURORADIOL, V15, P123
[9]   INFLUENCE OF CONTRALATERAL OBSTRUCTIONS ON DOPPLER-FREQUENCY SPECTRAL-ANALYSIS OF IPSILATERAL STENOSES OF THE CAROTID ARTERIES [J].
FISCHER, M ;
ALEXANDER, K .
STROKE, 1985, 16 (05) :846-848
[10]  
FORCONI S, 1987, J CARDIOVASC SURG, V28, P715