Diurnal variation of corneal sensitivity and thickness

被引:146
作者
du Toit, R [1 ]
Vega, JA [1 ]
Fonn, D [1 ]
Simpson, T [1 ]
机构
[1] Univ Waterloo, Ctr Contact Lens Res, Waterloo, ON N2L 3G1, Canada
关键词
diurnal variation; corneal thickness; corneal sensitivity; optical pachymetry; pneumatic esthesiometer;
D O I
10.1097/00003226-200304000-00004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. Methods. A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00. Results. Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 +/- 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 +/- 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8; p < 0.05). Discussion. Corneal sensitivity correlated with corneal thickness: both were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.
引用
收藏
页码:205 / 209
页数:5
相关论文
共 32 条
[1]  
Belmonte C, 1999, INVEST OPHTH VIS SCI, V40, P513
[2]   EFFECT OF HUMIDITY ON THE DESWELLING FUNCTION OF THE HUMAN CORNEA [J].
BOURASSA, S ;
BENJAMIN, WJ ;
BOLTZ, RL .
CURRENT EYE RESEARCH, 1991, 10 (06) :493-500
[3]  
COHEN SR, 1990, INVEST OPHTH VIS SCI, V31, P1282
[4]  
Cox I, 1990, INT CONTACT LENS CLI, V17, P134
[5]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[6]  
Fonn D, 1999, INVEST OPHTH VIS SCI, V40, P3116
[7]   Diurnal variations in human corneal thickness [J].
Harper, CL ;
Boulton, ME ;
Bennett, D ;
Marcyniuk, B ;
JarvisEvans, JH ;
Tullo, AB ;
Ridgway, AE .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (12) :1068-1072
[8]  
HOLDEN BA, 1982, INVEST OPHTH VIS SCI, V22, P343
[9]  
HOLDEN BA, 1983, INVEST OPHTH VIS SCI, V24, P218
[10]  
HOLDEN BA, 1980, INVEST OPHTH VIS SCI, V19, P1394