Development of insulated isothermal PCR for rapid on-site malaria detection

被引:35
作者
Chua, Kek Heng [1 ]
Lee, Ping Chin [2 ]
Chai, Hwa Chia [1 ]
机构
[1] Univ Malaya, Dept Biomed Sci, Fac Med, Kuala Lumpur 50603, Malaysia
[2] Univ Malaysia Sabah, Sch Sci & Technol, Kota Kinabalu 88400, Sabah, Malaysia
关键词
Plasmodium species; Diagnostic test; Insulated isothermal polymerase chain reaction (iiPCR); Endemic rural areas; POCKIT (TM); PLASMODIUM-FALCIPARUM MALARIA; SENSITIVE DETECTION; AMPLIFICATION LAMP; DIAGNOSIS; PERFORMANCE; CONVECTION; MICROSCOPY; VIRUS; TESTS; TUBE;
D O I
10.1186/s12936-016-1183-z
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: Detection of Plasmodium spp. is sometimes inconvenient especially in rural areas that are distant from a laboratory. In this study a portable diagnostic test of Plasmodium spp. was developed using insulated isothermal polymerase chain reaction (iiPCR) as an alternative approach to improve this situation. Methods: A pair of universal primers and probe were designed to amplify and detect gene encoding 18S small subunit rRNA of Plasmodium spp using iiPCR method in a portable device, POCKIT (TM). The efficiency and detection limit of the assay were evaluated using quantitative real-time polymerase chain reaction (qPCR) approach before being subjected to testing in POCKIT (TM). Detection results of POCKIT (TM) were displayed as '+', '-' or '?' based on the fluorescence ratio after/before reaction. A total of 55 and 35 samples from malaria patients and healthy subjects, respectively, were screened to evaluate the feasibility of this newly designed iiPCR assay. Results: The iiPCR assay allowed the detection of various species of Plasmodium, including those infecting humans (Plasmodium falciparum, P. vivax, P. knowlesi, P. malariae, P. ovale), monkeys, birds, and rodents. Efficiency of the assay achieved 96.9 % while the lower detection limit was >= 100 copies of plasmodial DNA. Specificity of the assay was assured as it could not detect human, bacterial and other parasitic DNA. Among the 55 clinical samples tested, 47 (85.4 %) of them were detected as positive by POCKIT (TM). Four (7.3 %) samples with fluorescence ratio after/before reaction of < 1.2 were reported as negative while another four (7.3 %) were ambiguously detected as they had fluorescence ratios between 1.2 and 1.3. The fluorescence ratio was not found to be associated with the copy number of plasmodial DNA. This approach can only be considered as a qualitative method. Conclusions: The portable iiPCR system may serve as an alternative approach for preliminary screening of malaria in endemic rural areas. The system may also be useful for detecting animal malaria in the field. Although it is not as quantitative as qPCR method, it is comparatively fast and easy to handle. It is believed that the POCKIT-iiPCR assay is able to achieve 100 % sensitivity if increased amount of DNA from each sample is used. The iiPCR assay can also be upgraded in future to detect multiple Plasmodium spp. at the same time by designing the specific primers and probes.
引用
收藏
页数:10
相关论文
共 34 条
[1]  
[Anonymous], 2014, WORLD MAL REP 2014
[2]   Ensuring quality and access for malaria diagnosis: how can it be achieved? [J].
Bell, David ;
Wongsrichanalai, Chansuda ;
Barnwell, John W. .
NATURE REVIEWS MICROBIOLOGY, 2006, 4 (09) :682-695
[3]  
Buchachart Kasinee, 2004, Southeast Asian Journal of Tropical Medicine and Public Health, V35, P35
[4]   BLAST plus : architecture and applications [J].
Camacho, Christiam ;
Coulouris, George ;
Avagyan, Vahram ;
Ma, Ning ;
Papadopoulos, Jason ;
Bealer, Kevin ;
Madden, Thomas L. .
BMC BIOINFORMATICS, 2009, 10
[5]   A thermally baffled device for highly stabilized convective PCR [J].
Chang, Hsiao-Fen Grace ;
Tsai, Yun-Long ;
Tsai, Chuan-Fu ;
Lin, Ching-Ko ;
Lee, Pei-Yu ;
Teng, Ping-Hua ;
Su, Chen ;
Jeng, Chien-Chung .
BIOTECHNOLOGY JOURNAL, 2012, 7 (05) :662-666
[6]   Hexaplex PCR Detection System for Identification of Five Human Plasmodium Species with an Internal Control [J].
Chew, Ching Hoong ;
Lim, Yvonne Ai Lian ;
Lee, Ping Chin ;
Mahmud, Rohela ;
Chua, Kek Heng .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (12) :4012-4019
[7]   Rapid DNA amplification in a capillary tube by natural convection with a single isothermal heater [J].
Chou, Wen Pin ;
Chen, Ping Hei ;
Miao, Ming, Jr. ;
Kuo, Long Sheng ;
Yeh, Shiou Hwei ;
Chen, Pei Jer .
BIOTECHNIQUES, 2011, 50 (01) :52-57
[8]   Loop-mediated isothermal amplification (LAMP) for point-of-care detection of asymptomatic low-density malaria parasite carriers in Zanzibar [J].
Cook, Jackie ;
Aydin-Schmidt, Berit ;
Gonzalez, Iveth J. ;
Bell, David ;
Edlund, Elin ;
Nassor, Majda H. ;
Msellem, Mwinyi ;
Ali, Abdullah ;
Abass, Ali K. ;
Martensson, Andreas ;
Bjorkman, Anders .
MALARIA JOURNAL, 2015, 14
[9]   Invalid result of Plasmodium falciparum malaria detection with the BinaxNOW Malaria rapid diagnostic test [J].
Durand, F ;
Faure, O ;
Brion, JP ;
Pelloux, H .
JOURNAL OF MEDICAL MICROBIOLOGY, 2005, 54 (11) :1115-1115
[10]  
Fernando S D, 2004, Ceylon Med J, V49, P7