Multislice Perfusion of the Kidneys Using Parallel Imaging: Image Acquisition and Analysis Strategies

被引:54
作者
Gardener, Alexander G. [1 ]
Francis, Susan T. [1 ]
机构
[1] Univ Nottingham, Sir Peter Mansfield Magnet Resonance Ctr, Sch Phys & Astron, Nottingham NG7 2RD, England
关键词
Arterial spin labeling; kidney perfusion; SE-EPI FAIR; True-FISP FAIR; perfusion imaging; parallel imaging; DYNAMIC MRI; IN-VIVO; 3.0; T; OPTIMIZATION; PULSES; ANGIOGRAPHY; EXPERIENCE; WATER; ASL;
D O I
10.1002/mrm.22387
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Flow-sensitive alternating inversion recovery arterial spin labeling with parallel imaging acquisition is used to acquire single-shot, multislice perfusion maps of the kidney. A considerable problem for arterial spin labeling methods, which are based on sequential subtraction, is the movement of the kidneys due to respiratory motion between acquisitions. The effects of breathing strategy (free, respiratory-triggered and breath hold) are studied and the use of background suppression is investigated. The application of movement correction by image registration is assessed and perfusion rates are measured. Postacquisition image realignment is shown to improve visual quality and subsequent perfusion quantification. Using such correction, data can be collected from free breathing alone, without the need for a good respiratory trace and in the shortest overall acquisition time, advantageous for patient comfort. The addition of background suppression to arterial spin labeling data is shown to reduce the perfusion signal-to-noise ratio and underestimate perfusion. Magn Reson Med 63:1627-1636, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1627 / 1636
页数:10
相关论文
共 30 条
[1]
Magnetic resonance angiography (MRA) in renally impaired patients: When and how [J].
Bongartz, Georg ;
Mayr, Michael ;
Bilecen, Deniz .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (02) :213-219
[2]
Contrast agent-associated nephrotoxicity [J].
Briguori, C ;
Tavano, D ;
Colombo, A .
PROGRESS IN CARDIOVASCULAR DISEASES, 2003, 45 (06) :493-503
[3]
MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results [J].
de Bazelaire, CMJ ;
Duhamel, GD ;
Rofsky, NM ;
Alsop, DC .
RADIOLOGY, 2004, 230 (03) :652-659
[4]
Magnetic resonance imaging as a sole method for the morphological and functional evaluation of live kidney donors [J].
El-Diasty, TA ;
El-Ghar, MEA ;
Shokeir, AA ;
Gad, HM ;
Wafa, EW ;
El-Azab, ME ;
El-Din, ABS ;
Ghoneim, MA .
BJU INTERNATIONAL, 2005, 96 (01) :111-116
[5]
Nephrogenic systemic fibrosis: is any contrast safe in renal failure? [J].
Endre, Z. H. .
INTERNAL MEDICINE JOURNAL, 2007, 37 (07) :429-431
[6]
ANALYSIS OF T2 LIMITATIONS AND OFF-RESONANCE EFFECTS ON SPATIAL-RESOLUTION AND ARTIFACTS IN ECHO-PLANAR IMAGING [J].
FARZANEH, F ;
RIEDERER, SJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (01) :123-139
[7]
Perfusion MR imaging with FAIR true FISP spin labeling in patients with and without renal artery stenosis: Initial experience [J].
Fenchel, M ;
Martirosian, P ;
Langanke, J ;
Giersch, J ;
Miller, S ;
Stauder, NI ;
Kramer, U ;
Claussen, CD ;
Schick, F .
RADIOLOGY, 2006, 238 (03) :1013-1021
[8]
Efficiency of inversion pulses for background suppressed arterial spin labeling [J].
Garcia, DM ;
Duhamel, G ;
Alsop, DC .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :366-372
[9]
Movement correction of the kidney in dynamic MRI scans using FFT phase difference movement detection [J].
Giele, ELW ;
de Priester, JA ;
Blom, JA ;
den Boer, JA ;
van Engelshoven, JMA ;
Hasman, A ;
Geerlings, M .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (06) :741-749
[10]
MRI of the liver: Can True FISP replace HASTE? [J].
Herborn, CU ;
Vogt, F ;
Lauenstein, TC ;
Goyen, M ;
Debatin, JF ;
Ruehm, SG .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (02) :190-196