Clinical utility of dual active deflection flexible ureteroscope during upper tract ureteropyeloscopy

被引:31
作者
Ankem, MK
Lowry, PS
Slovick, RW
del Rio, AM
Nakada, SY
机构
[1] Univ Wisconsin, Sch Med, Dept Surg, Clin Sci Ctr G5 339,Div Urol, Madison, WI 53792 USA
[2] Texas A&M Univ, Coll Med, Scott & White Mem Hosp, Div Urol, Temple, TX 76508 USA
关键词
D O I
10.1016/j.urology.2004.04.011
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To evaluate the clinical utility of a dual active deflection ACMI DUR-8 Elite ureteroscope in a referral endourology practice. Methods. Retrospective chart review was performed on 54 consecutive patients who underwent flexible ureteroscopy by a single surgeon (S.Y.N.) from February to July 2003. Cases in which standard flexible ureteroscopes alone could complete the procedure, cases in which standard flexible ureteroscopy could not complete the procedure and the DUR-8 Elite ureteroscope did, and cases in which both ureteroscopes failed to complete the procedure were analyzed. Results. A total of 54 procedures were performed on 37 patients. Three cases were not analyzed because they were distal ureter procedures. Of the remaining 51 procedures, 6 were removed from analysis because they were second-look procedures. When classified by diagnosis, 27 patients had stones (79.4%), 5 had cancer (14.7%), and 1 had hematuria (2.9%). The global success rate was 91.1%. The average use rate of the DUR-8 was 28.9%, and the success rate using the DUR-8 Elite was 69.2% in those cases in which it was necessary. Of the 13 cases in which the DUR-8 was used, 61.5% were for lower pole pathologic findings. The DUR Elite use and success rate in the lower pole was 57.1% and 75%, respectively. A statistically significant association was found between the diagnosis and procedure location (P = 0.00128). Conclusions. Our preliminary data indicate that the dual deflecting DUR-8 Elite ureteroscope may be helpful in cases in which the single deflection flexible instruments fail to access and treat upper urinary tract pathologic findings.
引用
收藏
页码:430 / 434
页数:5
相关论文
共 12 条
[1]   Flexible ureteroscopes: A single center evaluation of the durability and function of the new endoscopes smaller than 9Fr [J].
Afane, JS ;
Olweny, EO ;
Bercowsky, E ;
Sundaram, CP ;
Dunn, MD ;
Shalhav, AL ;
McDougall, EM ;
Clayman, RV .
JOURNAL OF UROLOGY, 2000, 164 (04) :1164-1168
[2]   INTRARENAL ACCESS WITH THE FLEXIBLE URETEROPYELOSCOPE - EFFECTS OF ACTIVE AND PASSIVE TIP DEFLECTION [J].
BAGLEY, DH .
JOURNAL OF ENDOUROLOGY, 1993, 7 (03) :221-224
[3]   Are new-generation flexible ureteroscopes better than their predecessors? [J].
Chiu, KY ;
Cai, Y ;
Marcovich, R ;
Smith, AD ;
Lee, BR .
BJU INTERNATIONAL, 2004, 93 (01) :115-119
[4]  
CONLIN MJ, 2002, UROTRENDS, V7, P1
[5]  
CONLIN MJ, 2002, UROTRENDS, V7, P7
[6]   Retrograde ureteropyeloscopy for lower pole caliceal calculi [J].
Grasso, M ;
Ficazzola, M .
JOURNAL OF UROLOGY, 1999, 162 (06) :1904-1908
[7]   A 7.5 8.2 F ACTIVELY DEFLECTABLE, FLEXIBLE URETEROSCOPE - A NEW DEVICE FOR BOTH DIAGNOSTIC AND THERAPEUTIC UPPER URINARY-TRACT ENDOSCOPY [J].
GRASSO, M ;
BAGLEY, D .
UROLOGY, 1994, 43 (04) :435-441
[8]   Small diameter, actively deflectable, flexible ureteropyeloscopy [J].
Grasso, M ;
Bagley, D .
JOURNAL OF UROLOGY, 1998, 160 (05) :1648-1653
[9]  
Ihaka R., 1996, J COMPUTATIONAL GRAP, V5, P299, DOI [10.1080/10618600.1996.10474713, 10.2307/1390807, DOI 10.1080/10618600.1996.10474713]
[10]   Variables affecting deflection of a new third-generation flexible ureteropyeloscope (DUR-8 Elite) [J].
Lobik, L ;
Lopez-Pujals, A ;
Leveillee, RJ .
JOURNAL OF ENDOUROLOGY, 2003, 17 (09) :733-736