Reactivities of organic phase biosensors. 2. The amperometric behaviour of horseradish peroxidase immobilised on a platinum electrode modified with an electrosynthetic polyaniline film

被引:101
作者
Iwuoha, EI
de Villaverde, DS
Garcia, NP
Smyth, MR [1 ]
Pingarron, JM
机构
[1] Dublin City Univ, Sch Chem Sci, Biomed & Environm Sensor Technol Ctr, Dublin 9, Ireland
[2] Univ Complutense Madrid, Dept Quim Analit, E-28040 Madrid, Spain
关键词
polyaniline based biosensor; organic phase biosensor; organic phase enzyme electrode; peroxide sensor; polyaniline film doped with poly(vinylsulphonate); kinetics of organic phase horseradish peroxidase electrode;
D O I
10.1016/S0956-5663(97)00042-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An amperometric peroxide biosensor was prepared by electrochemical deposition of horseradish peroxidase (HRP) on a Pt disc electrode modified with polyaniline (PANI) film doped with polyvinyl sulphonate (PVS). Electrochemical characterisation of the PANI-PVS film (without HRP) indicates a conducting electroactive polymer that exhibits fast reversible electrochemistry in 1M HCl. The HRP-based sensor was stable and gave rise to reproducible steady state responses for up to two weeks, when operated as both organic phase and aqueous phase H(2)O(2) biosensors at -100 mV/Ag-AgCl and 25 degrees C. The aqueous phase for the H(2)O(2) assay was 0.05 M phosphate buffer, pH 6.88, while acetone, acetonitrile, propan-2-ol and tetrahydrofuran (THF) organic phases were used. The analyses of the calibration curves of the biosensor showed that the system followed a Michaelis-Menten kinetics when operated either as organic- or aqueous-phase biosensors. The kinetic parameters K(m)' (apparent Michaelis Menten constant), k(cat)' (apparent biosensor turnover rate constant), and k(cat)'/K(m)' biosensing efficiency parameter) were evaluated from the steady-state amperometric data obtained in the five solvent media. The values of the biosensor efficiency factor, k(cat)'/K(m)', show that the sensor exhibits greater efficiency for analyte detection when operated in organic-phase mode in acetonitrile medium than in aqueous buffer. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:749 / 761
页数:13
相关论文
共 45 条
  • [31] TEMPERATURE-DEPENDENCE OF CHARGE TRANSPORT PROCESSES IN SURFACE DEPOSITED REDOX POLYMER LAYERS
    LYONS, MEG
    FAY, HG
    VOS, JG
    KELLY, AJ
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 250 (01): : 207 - 211
  • [32] ELECTROCHEMICAL-BEHAVIOR OF VARIOUS POLYANILINE MORPHOLOGIES IN NONAQUEOUS ELECTROLYTES
    MICHAELSON, JC
    MCEVOY, AJ
    GRATZEL, M
    [J]. SYNTHETIC METALS, 1993, 55 (2-3) : 1564 - 1569
  • [33] MICROELECTRODE STUDIES OF THE SWITCHING OF POLYANILINE FILMS IN UNBUFFERED AND BUFFERED SOLUTIONS
    NYHOLM, L
    PETER, LM
    [J]. SYNTHETIC METALS, 1993, 55 (2-3) : 1509 - 1514
  • [34] Diffusion currents in concentrated redox solutions
    Paulson, SC
    Okerlund, ND
    White, HS
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (04) : 581 - 584
  • [35] ELECTROCHEMICAL-BEHAVIOR OF POLYANILINE FILMS IN ACETONITRILE
    PEKMEZ, N
    PEKMEZ, K
    YILDIZ, A
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 370 (1-2): : 223 - 229
  • [36] Effect of quaternization of the glucose oxidase ''wiring'' redox polymer on the maximum current densities of glucose electrodes
    Rajagopalan, R
    Aoki, A
    Heller, A
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1996, 100 (09) : 3719 - 3727
  • [37] ORGANIC-PHASE ENZYME ELECTRODES
    SAINI, S
    HALL, GF
    DOWNS, MEA
    TURNER, APF
    [J]. ANALYTICA CHIMICA ACTA, 1991, 249 (01) : 1 - 15
  • [38] Conducting polymer based amperometric enzyme electrodes
    Schuhmann, W
    [J]. MIKROCHIMICA ACTA, 1995, 121 (1-4) : 1 - 29
  • [39] Shaolin M., 1991, J ELECTROANAL CH INF, V304, P7
  • [40] Shaolin M., 1994, J ELECTROANAL CHEM, V370, P135