On-column electrochemical reactions accompanying the electrospray process

被引:20
作者
Liu, SY [1 ]
Griffiths, WJ [1 ]
Sjövall, J [1 ]
机构
[1] Karolinska Inst, Dept Med Biochem & Biophys, SE-17177 Stockholm, Sweden
关键词
D O I
10.1021/ac026066p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is well-established that electrochemical reactions can occur within the capillary of an electrospray (ES) devise coupled to a mass spectrometer. In fact, such reactions must occur to maintain charge balance during the ES process. However, electrochemical reactions occurring distal to the capillary as a result of the high potential applied to the capillary have not been thoroughly investigated. In the present communication, we show that electrochemical processes can occur on a high performance liquid chromatography (HPLC) column coupled to an ES capillary. On-column solvent electrolysis is proposed to generate free radicals, which can subsequently initiate analyte oxidation. Oxidation of steroid sulfates possessing a reactive double bond between C-5 and C-6 is demonstrated. The possibility of similar reactions occurring within peptides possessing a site of unsaturation is also considered.
引用
收藏
页码:1022 / 1030
页数:9
相关论文
共 22 条
[1]   DIRECT COUPLING OF PACKED FUSED-SILICA LIQUID-CHROMATOGRAPHIC COLUMNS TO A MAGNETIC-SECTOR MASS-SPECTROMETER AND APPLICATION TO POLAR THERMOLABILE COMPOUNDS [J].
ALBORN, H ;
STENHAGEN, G .
JOURNAL OF CHROMATOGRAPHY, 1985, 323 (01) :47-66
[2]   MICRO-ELECTROSPRAY - ZEPTOMOLE-ATTOMOLE PER MICROLITER SENSITIVITY FOR PEPTIDES [J].
ANDREN, PE ;
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (09) :867-869
[3]   MECHANISM OF ELECTROSPRAY MASS-SPECTROMETRY - ELECTROSPRAY AS AN ELECTROLYSIS CELL [J].
BLADES, AT ;
IKONOMOU, MG ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (19) :2109-2114
[4]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[5]   Interfaces for coupled liquid-phase separation/mass spectrometry techniques.: An update on recent developments [J].
Gelpí, E .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (03) :241-253
[6]   Electrospray and tandem mass spectrometry in biochemistry [J].
Griffiths, WJ ;
Jonsson, AP ;
Liu, SY ;
Rai, DK ;
Wang, YQ .
BIOCHEMICAL JOURNAL, 2001, 355 :545-561
[7]  
Griffiths WJ, 1999, RAPID COMMUN MASS SP, V13, P1595, DOI 10.1002/(SICI)1097-0231(19990815)13:15<1595::AID-RCM681>3.3.CO
[8]  
2-T
[9]   ELECTROSPRAY ION SPRAY - A COMPARISON OF MECHANISMS AND PERFORMANCE [J].
IKONOMOU, MG ;
BLADES, AT ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :1989-1998
[10]   Electrochemically assisted Fenton reaction:: reaction of hydroxyl radicals with xenobiotics followed by on-line analysis with high-performance liquid chromatography/tandem mass spectrometry [J].
Jurva, U ;
Wikström, HV ;
Bruins, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (20) :1934-1940