Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode

被引:239
作者
Salimi, A
Compton, RG
Hallaj, R
机构
[1] Kurdistan Univ, Dept Chem, Sanandaj, Iran
[2] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
glucose; biosensor; sol-gel; carbon nanotube; glucose oxidase; amperometry;
D O I
10.1016/j.ab.2004.06.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3V (vs saturated calomel electrode) in 0.05M phosphate buffer solution (pH 7.4) with linear response range of 0.220 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 pM (S/N = 3). The response time of the electrode is < 5 s when it is stored dried at 4degreesC, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 49 条
[1]   Covalent attachment of osmium complexes to glucose oxidase and the application of the resulting modified enzyme in an enzyme switch responsive to glucose [J].
Battaglini, F ;
Bartlett, PN ;
Wang, JH .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :502-509
[2]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[3]   Amperometric determination of 6-mercaptopurine on functionalized multi-wall carbon nanotubes modified electrode by liquid chromatography coupled with microdialysis and its application to pharmacokinetics in rabbit [J].
Cao, XN ;
Lin, L ;
Zhou, YY ;
Shi, GY ;
Zhang, W ;
Yamamoto, K ;
Jin, LT .
TALANTA, 2003, 60 (05) :1063-1070
[4]   Sol-gel-derived titanium oxide/copolymer composite based glucose biosensor [J].
Chen, X ;
Dong, SJ .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (08) :999-1004
[5]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[6]   Construction of layer-by-layer self-assemblies of glucose oxidase and cationic polyelectrolyte onto glassy carbon electrodes and electrochemical study of the redox-mediated enzymatic activity [J].
Ferreyra, N ;
Coche-Guérente, L ;
Labbé, P .
ELECTROCHIMICA ACTA, 2004, 49 (03) :477-484
[7]   Adsorptive stripping voltammetric determination of 4-aminophenol at a single-wall carbon nanotubes film coated electrode [J].
Huang, WS ;
Hu, WB ;
Song, JC .
TALANTA, 2003, 61 (03) :411-416
[8]   Renewable silica sol-gel derived carbon composite based glucose biosensor [J].
Li, J ;
Chia, LS ;
Goh, NK ;
Tan, SN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 460 (1-2) :234-241
[9]   Investigation of the electrochemical and electrocatalytic behavior of single-wall carbon nanotube film on a glassy carbon electrode [J].
Luo, HX ;
Shi, ZJ ;
Li, NQ ;
Gu, ZN ;
Zhuang, QK .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :915-920
[10]   Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes [J].
Musameh, M ;
Wang, J ;
Merkoci, A ;
Lin, YH .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (10) :743-746