Subtle pulmonary abnormalities:: Detection on monitors with varying spatial resolutions and maximum luminance levels compared with detection on storage phosphor radiographic hard copies

被引:34
作者
Otto, D [1 ]
Bernhardt, TM [1 ]
Rapp-Bernhardt, U [1 ]
Ludwig, K [1 ]
Kästner, A [1 ]
Liehr, UB [1 ]
Döhring, W [1 ]
机构
[1] Otto Von Guericke Univ, Dept Diagnost Radiol, D-39120 Magdeburg, Germany
关键词
diagnostic radiology; observer performance; lung; interstitial disease; radiography; picture archiving and communication system (PACS); digital; storage phosphor; receiver operating characteristic curve (ROC);
D O I
10.1148/radiology.207.1.9530321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The purpose of this receiver operating characteristic study Was lo compare diagnostic efficacy with images displayed on monitors of varying spatial resolutions and maximum:luminance levels to that-with storage phosphor radiographic hard copies, MATERIALS AND METHODS: Seven types of simulated lesions were superimposed onto an anthropomorphic chest phantom. images were viewed by five radiologists on a 2,560 x 2,048-pixel monitor (maximum luminance, 75 foot-lamberts), on two 1,024 x 1,024 monitors with maximum luminance levels of 25 foot-lamberts and 75 foot-lamberts, respectively, as well as on hard copies. Monitor images were viewed both without and with systematic magnification. RESULTS:Overall visualization of the lesions was best on hard copies, but visualization on the 2,560 x 2,048 monitor was not found to be substantially different. Lines, reticular opacifications, and catheters were found to be particularly poorly visualized with the 1,024 x 1,024 monitor. These results could be statistically significantly improved only with a systematic:magnification; however, this involved a considerable increase in viewing time. Observer performance was markedly inferior with the 1,024 x 1,024 monitor with the lower luminance. CONCLUSION: Diagnostic performance With a 1,024 x 1,024 monitor is statistically significantly inferior to that with hard copies. A statistically significant improvement : can be achieved with a high-resolution 2,560 x 2,048 monitor with a maximum luminance of 75 foot-lamberts.
引用
收藏
页码:237 / 242
页数:6
相关论文
共 24 条
[21]   TOTAL DIGITAL RADIOLOGY DEPARTMENT - SPATIAL-RESOLUTION REQUIREMENTS [J].
SEELEY, GW ;
FISHER, HD ;
STEMPSKI, MO ;
BORGSTROM, M ;
BJELLAND, J ;
CAPP, MP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (02) :421-426
[22]   RECEIVER OPERATING CHARACTERISTIC ANALYSIS OF CHEST IMAGE INTERPRETATION WITH CONVENTIONAL, LASER-PRINTED, AND HIGH-RESOLUTION WORKSTATION IMAGES [J].
SLASKY, BS ;
GUR, D ;
GOOD, WF ;
COSTAGRECO, MA ;
HARRIS, KM ;
COOPERSTEIN, LA ;
ROCKETTE, HE .
RADIOLOGY, 1990, 174 (03) :775-780
[23]   DEVELOPMENT OF A 2,048X2,048-PIXEL IMAGE INTENSIFIER-TV DIGITAL RADIOGRAPHY SYSTEM - BASIC IMAGING PROPERTIES AND CLINICAL-APPLICATION [J].
TAKAHASHI, M ;
UENO, S ;
TSUCHIGAME, T ;
HIGASHIDA, Y ;
HIRATA, Y ;
MORIBE, N ;
TAKADA, T ;
KAMIYA, M ;
KOIKE, K .
INVESTIGATIVE RADIOLOGY, 1992, 27 (11) :898-907
[24]   DIGITIZED RADIOGRAPHS IN SKELETAL TRAUMA - A PERFORMANCE COMPARISON BETWEEN A DIGITAL WORKSTATION AND THE ORIGINAL FILM IMAGES [J].
WILSON, AJ ;
HODGE, JC .
RADIOLOGY, 1995, 196 (02) :565-568