Reproducibility of multichannel intraluminal electrical impedance monitoring of gastroesophageal reflux

被引:82
作者
Bredenoord, AJ
Weusten, BLAM
Timmer, R
Smout, AJPM
机构
[1] St Antonius Hosp, Dept Gastroenterol, NL-3430 EM Nieuwegein, Netherlands
[2] Univ Utrecht, Med Ctr, Gastroenterol Res Unit, Utrecht, Netherlands
关键词
D O I
10.1111/j.1572-0241.2005.41084.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVE: Esophageal impedance measurement is a novel method for gastroesophageal reflux monitoring. Reproducibility is an important aspect of every biomedical test. The aim of this study was therefore to asses the reproducibility of gastroesophageal reflux monitoring using impedance measurements. METHODS: Impedance and pH signals were recorded in 20 healthy volunteers during 90-min postprandial periods on two separate days. Hourly rates of gas, liquid, and mixed gas-liquid reflux episodes were measured in each recording period as well as percentage of time with pH < 4 and rate of acid reflux episodes. As a quantitative description of inter- and intraindividual variation for each variable, the mean percentage of covariation (100 x SD/mean: %COV) was calculated. As a second measure for reproducibility, Kendall's coefficients of concordance (W values) were calculated. RESULTS: For all variables, interindividual %COV was at least 50% higher than intraindividual %COV. Statistically significant concordances were found for gas reflux (W = 0.811 p = 0.04) and mixed reflux (W = 0.85, p = 0.03) while concordance for liquid reflux tended to be significant (W = 0.75, p = 0.08). This was comparable to the reproducibility of the number of acid reflux episodes and percentage of time with pH < 4 (W = 0.78, p = 0.05 and W = 0.88, p = 0.02, respectively). CONCLUSION: Postprandial gastroesophageal reflux data assessed with impedance monitoring are as reproducible as assessed with pH monitoring.
引用
收藏
页码:265 / 269
页数:5
相关论文
共 22 条
[1]  
[Anonymous], 1991, J GASTROINTEST MOTIL, V3, P151, DOI DOI 10.1111/J.1365-2982.1991.TB00061.X
[2]   Aerophagia, gastric, and supragastric belching: a study using intraluminal electrical impedance monitoring [J].
Bredenoord, AJ ;
Weusten, BLAM ;
Sifrim, D ;
Timmer, R ;
Smout, AJPM .
GUT, 2004, 53 (11) :1561-1565
[3]   REPRODUCIBILITY OF LONG-TERM AMBULATORY ESOPHAGEAL COMBINED PH MANOMETRY [J].
EMDE, C ;
ARMSTRONG, D ;
CASTIGLIONE, F ;
CILLUFFO, T ;
RIECKEN, EO ;
BLUM, AL .
GASTROENTEROLOGY, 1991, 100 (06) :1630-1637
[4]   Barrett's esophagus [J].
Falk, GW .
GASTROENTEROLOGY, 2002, 122 (06) :1569-1591
[5]   MEASURING ESOPHAGEAL MOTILITY WITH A NEW INTRALUMINAL IMPEDANCE DEVICE - FIRST CLINICAL-RESULTS IN REFLUX PATIENTS [J].
FASS, J ;
SILNY, J ;
BRAUN, J ;
HEINDRICHS, U ;
DREUW, B ;
SCHUMPELICK, V ;
RAU, G .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1994, 29 (08) :693-702
[6]   Reliability of 24-hour oesophageal pH monitoring under standardized conditions [J].
Franzén, T ;
Grahn, LT .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2002, 37 (01) :6-8
[7]   REPRODUCIBILITY OF AMBULATORY ESOPHAGEAL PH MONITORING [J].
JOHNSSON, F ;
JOELSSON, B .
GUT, 1988, 29 (07) :886-889
[8]   The role of non-acid reflux in gastro-oesophageal reflux disease [J].
Katz, PO .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2000, 14 (12) :1539-1551
[9]   CLINICAL BIOSTATISTICS .54. THE BIOSTATISTICS OF CONCORDANCE [J].
KRAMER, MS ;
FEINSTEIN, AR .
CLINICAL PHARMACOLOGY & THERAPEUTICS, 1981, 29 (01) :111-123
[10]  
LEAR C. S. C., 1965, ARCH ORAL BIOL, V10, P83, DOI 10.1016/0003-9969(65)90060-9