Response behavior of sodium-selective electrodes modified by surface attachment of the anticoagulant polysaccharides heparin and chondroitin sulfate

被引:11
作者
Badr, IHA
Feiler, J
Bachas, LG [1 ]
机构
[1] Univ Kentucky, Dept Chem, Lexington, KY 40506 USA
[2] Univ Kentucky, Ctr Membrane Sci, Lexington, KY 40506 USA
基金
美国国家航空航天局;
关键词
membrane electrodes; cellulose triacetate; heparin; chondroitin sulfate; ion-selective electrodes; biocompatibility;
D O I
10.1016/j.talanta.2004.06.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different polysaccharides with anticoagulant activities, heparin and chondroitin sulfate, were used to modify the surface of sodium-selective electrodes based on asymmetric cellulose triacetate (CTA) membranes. The membranes were formulated with sodium ionophore X, anionic additive. and o-nitrophenyl octyl ether. The response behavior of the surface-modified sodium electrodes was compared with that of control CTA. as well as poly(vinyl chloride) (PVC)-based sodium-selective electrodes. It was found that the selectivity coefficients obtained with the surface modified CTA membrane electrodes were slightly higher than those of the control, but in the case of heparin-modified electrode,; they still met the requirements for analysis of sodium in physiological fluids within an error of <1%; the corresponding error for chondroitin sulfate-modified electrodes was also <1% except for the case of potassium ion in which the error was 1.3%. Likewise, it was found that other response characteristics, such as detection limit, linear range, slope of the response plot, selectivity pattern, and response time were comparable in both the control and the polysaccharide-modified electrodes. Therefore, the surface modification does not significantly alter the response behavior of the sensors. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 266
页数:6
相关论文
共 43 条
[1]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[2]   Ion sensors: current limits and new trends [J].
Bakker, E ;
Diamond, D ;
Lewenstam, A ;
Pretsch, E .
ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) :11-18
[3]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[4]  
Barbucci R, 1996, POLYM ADVAN TECHNOL, V7, P675, DOI 10.1002/(SICI)1099-1581(199608)7:8<675::AID-PAT609>3.0.CO
[5]  
2-U
[6]   Bedside Clinical Chemistry: From Catheter Tip Sensor Chips Towards Micro Total Analysis Systems [J].
Bergveld, P. .
BIOMEDICAL MICRODEVICES, 2000, 2 (03) :185-195
[7]   Improving the blood compatibility of ion-selective electrodes by employing poly(MPC-co-BMA), a copolymer containing phosphorylcholine, as a membrane coating [J].
Berrocal, MJ ;
Johnson, RD ;
Badr, IHA ;
Liu, MD ;
Gao, DY ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3644-3648
[8]   Reducing the thrombogenicity of ion-selective electrode membranes through the use of a silicone-modified segmented polyurethane [J].
Berrocal, MJ ;
Badr, IHA ;
Gao, DO ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5328-5333
[9]   THE ANTICOAGULANT EFFECT OF CHONDROITIN-4-SULFATE [J].
BJORNSSON, TD ;
NASH, PV ;
SCHATEN, R .
THROMBOSIS RESEARCH, 1982, 27 (01) :15-21
[10]   Effect of surface-attached heparin on the response of potassium-selective electrodes [J].
Brooks, HA ;
Allen, JR ;
Feldhoff, PW ;
Bachas, LG .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1439-1443