PVC MATRIX MEMBRANE SENSORS FOR POTENTIOMETRIC DETERMINATION OF ARECOLINE

被引:4
作者
Abounassif, A. [1 ]
Al-Hadiya, B. M. [2 ]
Mostafa, Gamal A. E. [1 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11451, Saudi Arabia
[2] King Saud Univ, Coll Pharm, Dept Clin Pharm, Riyadh 11451, Saudi Arabia
关键词
arecoline; HBr; phosphomolybdic acid; phosphotungstic acid; potentiometry; PVC; sodium tetraphenyl borate; MASS-SPECTROMETRY; ARECA NUT; RISK;
D O I
10.1080/10739141003591517
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction and electrochemical response characteristics of Poly (vinyl chloride) (PVC) membrane sensors for arecoline HBr (AR) are described. The sensing membranes incorporate ion association complexes of (AR) cation and sodium tetraphenyl borate (NaTPB) (sensor 1) or phosphomolybdic acid (PMA) (sensor 2) or phosphotungstic acid (PTA) (sensor 3) as electroactive materials. The sensors display a fast, stable and near-Nernstian response over a relative wide AR concentration range (1x10-2-4x10-5M) and (1x10-2 to 5x10-6M), with cationic slopes of 52.5, 50.5 and 51.5mV per concentration decade for sensor 1, 2, and 3, respectively over a pH range of 3.0-6.0. The sensors show good discrimination of AR from several inorganic and organic compounds. The direct determination of 1.5-2360.0g/ml of AR show an average recovery of 99.0, 98.5 and 99.5% and a mean relative standard deviation of 1.7, 1.6 and 1.5% at 200.0g/ml for sensor 1, 2 and 3 respectively. The proposed sensors have been applied for direct determination of AR in human saliva. The results obtained for determination of AR in saliva using the proposed method comparable favorably with those obtained using HPLC method.
引用
收藏
页码:165 / 177
页数:13
相关论文
共 28 条
[1]  
ANTHONY C, 2004, CLARKES ANAL DRUGS P, V2
[2]  
Carggs A. A., 1974, J CHEM EDUC, V51, P541, DOI DOI 10.1021/ED051P541
[3]   Sensitive cadmium potentiometric sensor based on 4-hydroxy salophen as a fast tool for water samples analysis [J].
Ensafi, Ali A. ;
Meghdadi, S. ;
Sedighi, S. .
DESALINATION, 2009, 242 (1-3) :336-345
[4]   Chloride selective potentiometric sensor based on a newly synthesized hydrogen bonding anion receptor [J].
Gupta, Vinod K. ;
Goyal, R. N. ;
Sharma, Ram A. .
ELECTROCHIMICA ACTA, 2009, 54 (17) :4216-4222
[5]   A NOVEL FERROIN MEMBRANE SENSOR FOR POTENTIOMETRIC DETERMINATION OF IRON [J].
HASSAN, SSM ;
MARZOUK, SAM .
TALANTA, 1994, 41 (06) :891-899
[6]   QUANTITATIVE-DETERMINATION OF ARECOLINE IN PLASMA BY GAS-CHROMATOGRAPHY CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
HAYES, MJ ;
KHEMANI, L ;
BAX, M ;
ALKALAY, D .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (11) :1005-1009
[7]  
International Agency for Research on Cancer (IARC), 2004, MON EV CARC RISKS HU, V85
[8]  
*IUPAC AN CHEM DIV, 1994, ELECTRODE PURE APPL, V66, P2527
[9]  
Jeffery G., 1989, ORGANIC ANAL USING I, V2
[10]   Role of areca nut in betel quid-associated chemical carcinogenesis: current awareness and future perspectives [J].
Jeng, JH ;
Chang, MC ;
Hahn, LJ .
ORAL ONCOLOGY, 2001, 37 (06) :477-492