Removal of arterial wall calcifications in CT angiography by local subtraction

被引:20
作者
van Straten, M
Venema, HW
Streekstra, GJ
Reekers, JA
den Heeten, GJ
Grimbergen, CA
机构
[1] Acad Med Ctr, Dept Phys Med, NL-1100 DD Amsterdam, Netherlands
[2] Acad Med Ctr, Dept Radiol, NL-1100 DD Amsterdam, Netherlands
关键词
calcification; CT angiography; digital subtraction; partial volume effect; thresholding;
D O I
10.1118/1.1567271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
CT Angiography (CTA) is an established technique for the minimally invasive imaging of arteries. The technique of maximum intensity projection (MIP) is often used to get a comprehensive overview of the vascular anatomy. On a MIP, however, arterial wall calcifications may hinder the visualization of the arterial lumen. These calcifications are in direct contact with the contrast-enhanced blood, which makes removal difficult. We present a local subtraction method for the automatic removal of these calcifications. In our approach a second CT scan has to be made, prior to contrast injection. The calcifications in both scans are registered prior to subtraction to compensate for displacements in between the two scans. Local subtraction results are compared with results obtained by thresholding. The method was tested in a phantom and with data from four patients. The phantom represented an artery with different types of stenosis. Data were used from patients for which CTA of the renal arteries was performed. For two patients the electrocardiogram (ECG) was recorded during the CTA examination, making retrospective cardiac gated reconstructions possible. Both the phantom and the patient study showed that the local subtraction method is capable of removing calcifications and visualizing the residual lumen. In the patient study it appeared that some artifacts remained for higher pitch values. We conclude that the local subtraction' method is less subjective and more accurate than thresholding. Best results are obtained by use of a small pitch, at the expense of the volume covered during a single breath hold. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:761 / 770
页数:10
相关论文
共 21 条
[1]
[Anonymous], NUMERICAL RECIPES C
[2]
Assessment of renal artery stenosis with CT angiography: Usefulness of multiplanar reformation, quantitative stenosis measurements, and densitometric analysis of renal parenchymal enhancement as adjuncts to MIP film reading [J].
Berg, MH ;
Manninen, HI ;
Vanninen, RL ;
Vainio, PA ;
Soimakallio, S .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) :533-540
[3]
CT ANGIOGRAPHY - APPLICATION TO THE EVALUATION OF CAROTID-ARTERY STENOSIS [J].
DILLON, EH ;
VANLEEUWEN, MS ;
FERNANDEZ, MA ;
EIKELBOOM, BC ;
MALI, WPTM .
RADIOLOGY, 1993, 189 (01) :211-219
[4]
RENAL ARTERIAL STENOSES - SPIRAL CT ANGIOGRAPHY [J].
GALANSKI, M ;
PROKOP, M ;
CHAVAN, A ;
SCHAEFER, CM ;
JANDELEIT, K ;
NISCHELSKY, JE .
RADIOLOGY, 1993, 189 (01) :185-192
[5]
Maximum stenosis of extracranial internal carotid artery: Effect of luminal morphology on stenosis measurement by using CT angiography and conventional DSA [J].
Hirai, T ;
Korogi, Y ;
Ono, K ;
Murata, Y ;
Takahashi, M ;
Suginohara, K ;
Uemura, S .
RADIOLOGY, 2001, 221 (03) :802-809
[6]
Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[7]
Renal artery stenosis: CT angiography - Comparison of real-time volume-rendering and maximum intensity projection algorithms [J].
Johnson, PT ;
Halpern, EJ ;
Kuszyk, BS ;
Heath, DG ;
Wechsler, RJ ;
Nazarian, LN ;
Gardiner, GA ;
Levin, DC ;
Fishman, EK .
RADIOLOGY, 1999, 211 (02) :337-343
[8]
ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart [J].
Kachelriess, M ;
Ulzheimer, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (08) :1881-1902
[9]
Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart [J].
Kachelriess, M ;
Kalender, WA .
MEDICAL PHYSICS, 1998, 25 (12) :2417-2431
[10]
Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates [J].
Karolczak, M ;
Schaller, S ;
Engelke, K ;
Lutz, A ;
Taubenreuther, U ;
Wiesent, K ;
Kalender, W .
MEDICAL PHYSICS, 2001, 28 (10) :2050-2069