In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging

被引:148
作者
Eckstein, F
Westhoff, J
Sittek, H
Maag, KP
Haubner, M
Faber, S
Englmeier, KH
Reiser, M
机构
[1] Univ Munich, Anat Anstalt, D-80336 Munich, Germany
[2] Klinikum Grosshadern, Inst Radiol Diagnost, D-81377 Munich, Germany
[3] Klinikum Grosshadern, Dept Med Informat Verarbeitung Biometrie & Epidem, D-81377 Munich, Germany
[4] GSF Forschungszentrum Umwelt & Gesundheit, Inst Med Informat & Syst Forsch, D-85764 Oberschleissheim, Germany
关键词
D O I
10.2214/ajr.170.3.9490936
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Previous studies suggest that MR imaging is capable of providing accurate data on knee joint cartilage volume and thickness in vitro, but the reproducibility of these data in living subjects has not been analyzed rigorously. Our aim was therefore to determine the in vivo reproducibility of volume-and thickness measurements from replicated data sets, applying three-dimensional (3D) postprocessing methods. SUBJECTS AND METHODS. Eight healthy volunteers were imaged six times at a resolution of 2 x 0.31 x 0.31 mm with a fat-suppressed fast low-angle shot 3D sequence, the knee being repositioned in between replicated examinations. Three-dimensional reconstructions of the articular cartilage surfaces were obtained from sagittal data sets, and the cartilage volumes were calculated. The thickness distribution was analyzed throughout the joint surfaces independent of the section orientation, using a previously validated 3D minimal-distance algorithm. RESULTS. In the volunteers, the coefficient of variation for replicated volume measurements ranged from 1.3% (patella) to 3.4% (lateral tibia), and the standard deviation of the individual cartilage volumes ranged from +/-16% (lateral tibia) to +/-22% (femur). The intraclass correlation coefficient ranged from .959 (lateral tibia) to .995 (patella). The interobserver evaluation was similar to the interscan reproducibility. The mean interscan deviation of the maximal cartilage thickness interval ranged from 0.1 to 0.3 cartilage thickness intervals (of 0.5 mm); only in rare cases did we record deviations greater than one thickness interval. CONCLUSION. MR imaging can be used to determine cartilage volume and thickness in the knee joints of living subjects with high precision, provided that a fat-suppressed gradient-echo sequence with adequate resolution and 3D digital image processing are used.
引用
收藏
页码:593 / 597
页数:5
相关论文
共 33 条
[1]   QUANTITATION OF ARTICULAR SURFACE-TOPOGRAPHY AND CARTILAGE THICKNESS IN KNEE JOINTS USING STEREOPHOTOGRAMMETRY [J].
ATESHIAN, GA ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1991, 24 (08) :761-776
[2]   INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY [J].
BARTKO, JJ .
PSYCHOLOGICAL REPORTS, 1966, 19 (01) :3-&
[3]   ARTICULAR CONTACT IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
KUIPER, JH ;
HUISKES, R ;
GROOTENBOER, HJ .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1019-1031
[4]   KNEE HYALINE CARTILAGE EVALUATED WITH MR IMAGING - A CADAVERIC STUDY INVOLVING MULTIPLE IMAGING SEQUENCES AND INTRAARTICULAR INJECTION OF GADOLINIUM AND SALINE SOLUTION [J].
CHANDNANI, VP ;
HO, C ;
CHU, P ;
TRUDELL, D ;
RESNICK, D .
RADIOLOGY, 1991, 178 (02) :557-561
[5]   SHOULD PERIMENOPAUSAL WOMEN BE SCREENED FOR OSTEOPOROSIS [J].
CUMMINGS, SR ;
BLACK, D .
ANNALS OF INTERNAL MEDICINE, 1986, 104 (06) :817-823
[6]   DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY [J].
DISLER, DG ;
MCCAULEY, TR ;
WIRTH, CR ;
FUCHS, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :377-382
[7]   Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM) [J].
Eckstein, F ;
Gavazzeni, A ;
Sittek, H ;
Haubner, M ;
Losch, A ;
Milz, S ;
Englmeier, KH ;
Schulte, E ;
Putz, R ;
Reiser, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :256-265
[8]   Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging [J].
Eckstein, F ;
Adam, C ;
Sittek, H ;
Becker, C ;
Milz, S ;
Schulte, E ;
Reiser, M ;
Putz, R .
JOURNAL OF BIOMECHANICS, 1997, 30 (03) :285-289
[9]   THE MORPHOLOGY OF ARTICULAR-CARTILAGE ASSESSED BY MAGNETIC-RESONANCE-IMAGING (MRI) - REPRODUCIBILITY AND ANATOMICAL CORRELATION [J].
ECKSTEIN, F ;
SITTEK, H ;
MILZ, S ;
PUTZ, R ;
REISER, M .
SURGICAL AND RADIOLOGIC ANATOMY, 1994, 16 (04) :429-438
[10]   Magnetic resonance chondro-crassometry (MR CCM): A method for accurate determination of articular cartilage thickness [J].
Eckstein, F ;
Sittek, H ;
Gavazzeni, A ;
Schulte, E ;
Milz, S ;
Kiefer, B ;
Reiser, M ;
Putz, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :89-96