Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization

被引:230
作者
Bacher, K
Bogaert, E
Lapere, R
De Wolf, D
Thierens, H
机构
[1] Univ Ghent, Dept Med Phys & Radiat Protect, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Dept Pediat Cardiol, B-9000 Ghent, Belgium
关键词
catheterization; pediatrics; radiation;
D O I
10.1161/01.CIR.0000151098.52656.3A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Because of the higher radiosensitivity of infants and children compared with adults, there is a need to evaluate the doses delivered to pediatric patients who undergo interventional cardiac procedures. However, knowledge of the effective dose in pediatric interventional cardiology is very limited. Methods and Results - For an accurate risk estimation, a patient-specific Monte Carlo simulation of the effective dose was set up in 60 patients with congenital heart disease who underwent diagnostic (n=28) or therapeutic (n=32) cardiac catheterization procedures. The dose-saving effect of using extra copper filtration in the x-ray beam was also investigated. For diagnostic cardiac catheterizations, a median effective dose of 4.6 mSv was found. Therapeutic procedures resulted in a higher median effective dose of 6.0 mSv because of the prolonged use of fluoroscopy. The overall effect of inserting extra copper filtration into the x-ray beam was a total effective dose reduction of 18% with no detrimental effect on image quality. An excellent correlation between the dose-area product and effective patient dose was found (r=0.95). Hence, dose-area product is suitable for online estimation of the effective dose with good accuracy. With all procedures included, the resulting median lifetime risk for stochastic effects was 0.08%. Conclusions - Because of the high radiation exposure, it is important to monitor patient dose by dose-area product instrumentation and to use additional beam filtration to keep the effective dose as low as possible in view of the sensitivity of the pediatric patients.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 30 条
[21]   Reduced radiation during cardiac catheterization of infants using acquisition zoom technology [J].
Ross, RD ;
Joshi, V ;
Carravallah, DJ ;
Morrow, WR .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (05) :691-693
[22]   RADIATION EXPOSURE AND EFFICACY OF EXPOSURE-REDUCTION TECHNIQUES DURING CARDIAC-CATHETERIZATION IN CHILDREN [J].
SCHUELER, BA ;
JULSRUD, PR ;
GRAY, JE ;
STEARS, JG ;
WU, KY .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :173-177
[23]  
Thijssen M, 1998, MANUAL CONTRAST DETA
[24]  
*UNSCEAR, 2000, SOURC EFF ION RAD, V1
[25]  
*US FDA, 1994, MED B, V24, P7
[26]   Correlation of patient skin doses in cardiac interventional radiology with dose-area product [J].
van de Putte, S ;
Verhaegen, F ;
Taeymans, Y ;
Thierens, H .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (869) :504-513
[27]   Patient dosimetry in interventional radiology using slow films [J].
Vano, E ;
Guibelalde, E ;
Fernandez, JM ;
Gonzalez, L ;
Ten, JI .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 :195-200
[28]   Dosimetric and radiation protection considerations based on some cases of patient skin injuries in interventional cardiology [J].
Vañó, E ;
Arranz, L ;
Sastre, JM ;
Moro, C ;
Ledo, A ;
Gárate, MT ;
Minguez, I .
BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (845) :510-516
[29]   Monte Carlo modelling of radiotherapy kV x-ray units [J].
Verhaegen, F ;
Nahum, AE ;
Van de Putte, S ;
Namito, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07) :1767-1789
[30]   RADIATION EXPOSURE TO THE CHILD DURING CARDIAC-CATHETERIZATION [J].
WALDMAN, JD ;
RUMMERFIELD, PS ;
GILPIN, EA ;
KIRKPATRICK, SE .
CIRCULATION, 1981, 64 (01) :158-163