摘要
A new hardware solution is proposed that allows one to automatically change the length of a chromatographic bed. The setup is based on the serial coupling of chromatographic columns using two rotor-stator valves (with N positions, N + 1 ports). Despite the use of a prototype setup requiring rather long connection tubing, only 9% loss in efficiency is observed for compounds with a retention factor above 4 compared to the efficiency expected on the basis of the individual column results. It has been demonstrated for a number of isocratic and gradient separations that the system allows one to realize considerable analysis time savings by adapting the total column length to the specific sample requirements and/or to the stage of method development wherein one is working. During method development, a separation on a short column length can first be used to rapidly gain insight into the composition of the sample, leaving fewer runs to be done on a column of maximal length (offering efficiencies that are inaccessible with individual column systems). The ease with which information can be obtained on columns of different lengths can furthermore be exploited for screening purposes to detect coeluting components in a stage wherein they still appear completely unresolved (i.e., have a resolution well below R-s = 0.5).
引用
收藏
页码:1054 / 1065
页数:12
相关论文
共 30 条
[1]   Investigation of the validity of the kinetic plot method to predict the performance of coupled column systems operated at very high pressures under different thermal conditions [J].
Cabooter, Deirdre ;
Lestremau, Francois ;
de Villiers, Andre ;
Broeckhoven, Ken ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) :3895-3903
[2]   Kinetic plot method as a tool to design coupled column systems producing 100,000 theoretical plates in the shortest possible time [J].
Cabooter, Deirdre ;
Lestremau, Francois ;
Lynen, Frederic ;
Sandra, Pat ;
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1212 (1-2) :23-34
[3]  
COULSON JM, 1999, CHEM ENG, V2
[4]   Fused-core particle technology as an alternative to sub-2-αm particles to achieve high separation efficiency with low backpressure [J].
Cunliffe, Jennifer M. ;
Maloney, Todd D. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (18) :3104-3109
[5]  
Desmet G, 2005, LC GC EUR, V18, P403
[6]   Practical constraints in the kinetic plot representation of chromatographic performance data: Theory and application to experimental data [J].
Desmet, G ;
Clicq, D ;
Nguyen, DTT ;
Guillarme, D ;
Rudaz, S ;
Veuthey, JL ;
Vervoort, N ;
Torok, G ;
Cabooter, D ;
Gzil, P .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2150-2162
[7]   Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology [J].
Desmet, G ;
Clicq, D ;
Gzil, P .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4058-4070
[8]   Theoretical calculation of the retention enthalpy effect on the viscous heat dissipation band broadening in high performance liquid chromatography columns with a fixed wall temperature [J].
Desmet, Gert .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1116 (1-2) :89-96
[9]  
Desmet G, 2009, LC GC EUR, V22, P70
[10]   Chromatographic classification and comparison of commercially available reversed-phase liquid chromatographic columns containing phenyl moieties using principal component analysis [J].
Euerby, Melvin R. ;
Petersson, Patrik ;
Campbell, William ;
Roe, Wendy .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) :138-151