Postoperative imaging of zygomaticomaxillary complex fractures using digital volume tomography

被引:47
作者
Heiland, M
Schulze, DK
Rother, U
Schmelzle, R
机构
[1] Univ Hamburg, Hosp Eppendorf, Dept Oral & Maxillofacial Surg, D-20246 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Dept Oral Radiol, D-20246 Hamburg, Germany
关键词
D O I
10.1016/j.joms.2004.05.215
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Three-dimensional imaging using digital volume tomography after reduction of zygomatico-maxillan, complex fractures was performed and evaluated. Patients and Methods: Ten patients admitted for surgical treatment of zygomaticomaxillary complex fractures were included in the study. All patients were male, aged 17 to 81 years (average, 43.8 years). Preoperative diagnostics and surgical treatment involving open reduction under general anesthesia were performed as usual. One to 3 days (average, 1.6 days) postoperatively, a digital volume tomography data set was generated using the NewTom 9000 (NIM s.r.l., Verona, Italy). After DICOM-import in eFilm Workstation 1.8.3 (Merge Technologies Inc, Milwaukee, WI), axial, coronal, and sagittal reconstructions were evaluated by 6 examiners with the help of 5 defined criteria. Results: One data set was sufficient to visualize all fracture sites of the midface in all patients. Postprocessing using eFilm was successfully performed in all cases. Best scoring results were found regarding bony), anchorage of screws and fitting of plates. Remarkable was the low level of metal artifacts in primary and secondary reconstructions, even in close proximity of the material. Most difficulty was encountered during the identification of the medial orbital wall, especially next to poorly ventilated ethmoidal cells. Osseous structures of older patients with decreased bone density proved difficult to visualize. Conclusion: Digital volume tomography using the NewTom 9000 is suitable for assessment of postoperative results after zygomaticomaxillary complex reduction. (C) 2004 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1387 / 1391
页数:5
相关论文
共 21 条
[1]   Radiation dose in dental radiology [J].
Cohnen, M ;
Kemper, J ;
Möbes, O ;
Pawelzik, J ;
Mödder, U .
EUROPEAN RADIOLOGY, 2002, 12 (03) :634-637
[2]   Analysis of treatment for isolated zygomaticomaxillary complex fractures [J].
Ellis, E ;
Kittidumkerng, W .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (04) :386-400
[3]  
FLINZBERG S, 2003, OSTEOSYNTHESE MUND K, V7, P289
[4]   3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil ISO-C3D) [J].
Heiland, M ;
Schulze, D ;
Adam, G ;
Schmelzle, R .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) :21-25
[5]   Erweiterte Diagnostik im Rahmen der operativen Weisheitszahnentfernung mittels digitaler VolumentomographieDigital volume tomography – an extension to the diagnostic procedures available for application before surgical removal of third molars [J].
Th. Heurich ;
C. Ziegler ;
H. Steveling ;
R. Wörtche ;
J. Mühling ;
St. Hassfeld .
Mund-, Kiefer- und Gesichtschirurgie, 2002, 6 (6) :427-432
[6]   Intraoperative computed tomography with the mobile CT Tomoscan M during surgical treatment of orbital fractures [J].
Hoelzle, F ;
Klein, M ;
Schwerdtner, O ;
Lueth, T ;
Albrecht, J ;
Hosten, N ;
Felix, R ;
Bier, J .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 30 (01) :26-31
[7]  
Hoffmann J, 2002, Mund Kiefer Gesichtschir, V6, P346
[8]   Botulinum toxin in the treatment of zygomatic fractures [J].
Kayikçioglu, A ;
Erk, Y ;
Mavili, E ;
Vargel, I ;
Özgür, F .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (01) :341-346
[9]   Three-dimensional CT with a modified C-arm image intensifier: Feasibility [J].
Linsenmaier, U ;
Rock, C ;
Euler, E ;
Wirth, S ;
Brandl, R ;
Kotsianos, D ;
Mutschler, W ;
Pfeifer, KJ .
RADIOLOGY, 2002, 224 (01) :286-292
[10]  
Manson P N, 1999, Arch Facial Plast Surg, V1, P25, DOI 10.1001/archfaci.1.1.25