Comparison of ECG-gated rectilinear vs. real-time radial K-space sampling schemes in cine true-FISP cardiac MRI

被引:12
作者
Boll, DT
Merkle, EM
Seaman, DM
Gilkeson, RC
Larson, AP
Simonetti, OP
Duerk, JL
Lewin, JS
机构
[1] Case Western Reserve Univ, Univ Hosp, Dept Radiol, Cleveland, OH 44106 USA
[2] Siemens Med Solutions, Cardiovasc MR Res Grp, Chicago, IL USA
关键词
cardiac MRI; volumetric analysis; radial; cine true-FISP;
D O I
10.1081/JCMR-200036124
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. To compare three k-space sampling schemes in cine True-FISP cardiac magnetic resonance imaging and to evaluate changes in calculated quantitative functional cardiac parameters as a function of underlying k-space sampling techniques. Material and Methods. Using a 1.5 T MR imaging system (Magnetom Sonata, Siemens Medical Solutions, Erlangen, Germany), three k-space data-sampling schemes: rectilinear (2.96 ms/1.58 ms/70degrees/12 s TR/TE/FA/AcquisitionTime), and two radial k-space acquisitions, with filtered back-projection (RADIAL) (2.45 ms/1.25 ms/50degrees/3.3 s TR/TE/FA/AT), and steady-state projection imaging with dynamic echotrain readout (SPIDER) (339 ms/1.62 ms/55degrees/1.8 s TR/TE/FA/AT) of a True-FISP sequence were applied in 10 healthy volunteers. Long- and short-axis breath-hold series were acquired and signal-to-noise ratios (SNR) for blood and myocardium were determined, as was contrast-to-noise ratios (CNR). Quantitative cardiac functional analysis included: determination of end-systolic/end-diastolic volumes, ejection fraction, and left ventricular mass. Functional analysis was performed by two independent readers three times for each volunteer and k-space sampling strategy. Statistical analysis evaluated the accuracy of the measurements obtained from each of the three sampling techniques and the intra- and interobserver reliability. Results. Intraobserver and interobserver reliability measures of functional data were homogeneous without statistically significant differences. Intraobserver correlation coefficients ranged from 0.94-0.99; interobserver correlation coefficients ranged from 0.97-0.99. Direct comparison of SPIDER- and RADIAL-sampled True-FISP sequences showed no statistically significant differences in measured functional parameters with interstudy correlation coefficients from 0.88-0.98. RADIAL and SPIDER images had better temporal resolution and were qualitatively judged to provide superior wall/blood border definition. Statistically significant differences were identified in each volumetric functional parameter when results from the rectilinear sampling acquisitions were compared with either radial or SPIDER sampling techniques. RADIAL and SPIDER results were consistently higher than volumetric measures obtained from the rectilinear data set. Conclusion. Employing faster sampling schemes led to enhanced signal homogeneity while maintaining the necessary CNR for estimation of functional cardiac parameters. Enhanced signal homogeneity and maintained CNR will most likely improve the accuracy of the cardiac functional parameter determination.
引用
收藏
页码:793 / 802
页数:10
相关论文
共 18 条
[1]   METHODS AND THEORY OF RELIABILITY [J].
BARTKO, JJ ;
CARPENTER, WT .
JOURNAL OF NERVOUS AND MENTAL DISEASE, 1976, 163 (05) :307-317
[2]   Measurement of left ventricular volume after anterior myocardial infarction: comparison of magnetic resonance imaging, echocardiography, and radionuclide ventriculography [J].
Darasz, KH ;
Underwood, SR ;
Bayliss, J ;
Forbat, SM ;
Keegan, J ;
Poole-Wilson, PA ;
Sutton, GC .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2002, 18 (02) :135-142
[3]   Rapid assessment of left ventricular volume by short axis cine MRI [J].
Forbat, SM ;
Sakrana, MA ;
Darasz, KH ;
ElDemerdash, F ;
Underwood, SR .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819) :221-225
[4]   VARIABLES PREDICTIVE OF SURVIVAL IN PATIENTS WITH CORONARY-DISEASE - SELECTION BY UNIVARIATE AND MULTIVARIATE ANALYSES FROM THE CLINICAL, ELECTROCARDIOGRAPHIC, EXERCISE, ARTERIOGRAPHIC, AND QUANTITATIVE ANGIOGRAPHIC EVALUATIONS [J].
HAMMERMEISTER, KE ;
DEROUEN, TA ;
DODGE, HT .
CIRCULATION, 1979, 59 (03) :421-430
[5]  
Heusch A, 1999, Eur J Ultrasound, V9, P245, DOI 10.1016/S0929-8266(99)00032-4
[6]  
KONERMANN M, 1992, Z KARDIOL, V81, P610
[7]   CARDIAC IMAGING USING GATED MAGNETIC-RESONANCE [J].
LANZER, P ;
BOTVINICK, EH ;
SCHILLER, NB ;
CROOKS, LE ;
ARAKAWA, M ;
KAUFMAN, L ;
DAVIS, PL ;
HERFKENS, R ;
LIPTON, MJ ;
HIGGINS, CB .
RADIOLOGY, 1984, 150 (01) :121-127
[8]   Real-time cardiac cine imaging with SPIDER: Steady-state projection imaging with dynamic echo-train readout [J].
Larson, AC ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (06) :1059-1066
[9]   Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precessiion [J].
Lee, VS ;
Resnick, D ;
Bundy, JM ;
Simonetti, OP ;
Lee, P ;
Weinreb, JC .
RADIOLOGY, 2002, 222 (03) :835-842
[10]   RETROSPECTIVE CARDIAC GATING - A REVIEW OF TECHNICAL ASPECTS AND FUTURE-DIRECTIONS [J].
LENZ, GW ;
HAACKE, EM ;
WHITE, RD .
MAGNETIC RESONANCE IMAGING, 1989, 7 (05) :445-455