Dual amperometric biosensor device for analysis of binary mixtures of phenols by multivariate calibration using partial least squares

被引:38
作者
Freire, RS
Ferreira, MMC
Durán, N
Kubota, LT
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
[2] Univ Mogi das Cruzes, Mogi Das Cruzes, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
phenolic compounds; amperometric biosensors; multichannel; multivariate calibration;
D O I
10.1016/S0003-2670(03)00414-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and reliable method for rapid evaluation of mixtures of phenolic compounds (phenol/chlorophenol, cathecol/phenol, cresol/chlorocresol and phenol/cresol) using a dual amperometric device is described. This new approach is based on the difference between the sensitivity of laccase and tyrosinase for different phenolic compounds. A multichannel potentiostat was used to monitor simultaneously laccase- and tyrosinase-based biosensors, and the data were treated using the partial least squares (PLS) chemometric algorithm. This system showed an excellent efficiency for the resolution of the phenolic mixtures. For example, in the phenollchlorophenol mixture it was studied the determination of individual species in a concentration range from 1.0 x 10(-6) to 10.0 X 10(-6) mol l(-1) obtaining relative standard deviations of 3.5 and 3.1% for phenol and chlorophenol, respectively. The excellent correlation between the estimated and the real concentrations can also be observed by the correlation coefficients (0.9958 and 0.9981 for phenol and chlorophenol, respectively). These results show that proposed methodology can be successfully employed to the simultaneous determination of phenolic compounds in mixtures, even in more diluted solutions. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:263 / 269
页数:7
相关论文
共 38 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]  
Beebe K.R., 1998, CHEMOMETRICS PRACTIC
[3]   Rate-limiting steps of tyrosinase-modified electrodes for the detection of catechol [J].
Burestedt, E ;
Narvaez, A ;
Ruzgas, T ;
Gorton, L ;
Emneus, J ;
Dominguez, E ;
MarkoVarga, G .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1605-1611
[4]   DETERMINATION OF PHENOL IN WASTES AND WATER USING AN ENZYME SENSOR [J].
CAMPANELLA, L ;
BEONE, T ;
SAMMARTINO, MP ;
TOMASSETTI, M .
ANALYST, 1993, 118 (08) :979-986
[5]   COMPARISON OF IMMOBILIZATION PROCEDURES FOR DEVELOPMENT OF AN ELECTROCHEMICAL PPO-BASED BIOSENSOR FOR ON LINE MONITORING OF A DEPURATION PROCESS [J].
CANOFENI, S ;
DISARIO, S ;
MELA, J ;
PILLOTON, R .
ANALYTICAL LETTERS, 1994, 27 (09) :1659-1669
[6]  
CARVALHO RM, 2000, ANAL CHIM ACTA, V420, P109, DOI DOI 10.1016/S0003-2670(00)01012-6
[7]   APPLICATION OF MULTICOMPONENT ANALYSIS TO THE SIMULTANEOUS RESOLUTION OF PHENOL COMPOUNDS IN MIXTURES .2. DEVELOPMENT OF A CLOSED-CIRCUIT EXTRACTION, ENRICHMENT AND BACK-EXTRACTION SYSTEM [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :103-109
[8]   APPLICATION OF MULTICOMPONENT ANALYSIS TO THE SIMULTANEOUS RESOLUTION OF PHENOL COMPOUNDS IN MIXTURES .1. DEVELOPMENT OF THE CALCULATION METHODS AND EXPERIMENTAL METHODOLOGY [J].
CLADERA, A ;
GOMEZ, E ;
ESTELA, JM ;
CERDA, V .
ANALYTICA CHIMICA ACTA, 1992, 267 (01) :95-102
[9]   Multicomponent sequential injection analysis determination of nitro-phenols in waters by on-line liquid-liquid extraction and preconcentration [J].
Cladera, A ;
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2000, 421 (02) :155-166
[10]   Laccase-based screen printed electrode for amperometric detection of phenolic compounds [J].
Freire, RS ;
Duran, N ;
Wang, J ;
Kubota, LT .
ANALYTICAL LETTERS, 2002, 35 (01) :29-38