Amperometric biosensor-based flow-through microdetector for microdialysis applications

被引:14
作者
Gáspár, S
Wang, XW
Suzuki, H
Csöregi, E
机构
[1] Lund Univ, Dept Biotechnol, S-22100 Lund, Sweden
[2] Univ Tsukuba, Inst Mat Sci, Tsukuba, Ibaraki 3058573, Japan
关键词
biosensors; electrochemical microcell; microdetector; microdialysis;
D O I
10.1016/j.aca.2004.07.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow-through electrochemical microcell was fabricated, in order to be used as an on-line detector in microdialysis-based investigations. The microcell is obtained by sandwich-like assembling the electrode system patterned on a glass chip and a silicon rubber gasket bearing the fluidic elements (inlet, outlet, flow channel, and containers for reference and counter electrode). Four Pt microelectrodes (100 mum x 100 mum squares), a Pt counter electrode, and a Ag reference electrode were patterned on a 9 mm x 14 mm glass chip by thin film technology. The silicon rubber cover was fabricated using a polydimethylsiloxane based precursor and a plastic mold, and it avoids significant dilution of the sample before getting in contact with the sensing electrodes. The microdetector can be directly connected to the outlet of the microdialysis probe reducing significantly the delay between sampling and detection. The microelectrodes were modified with enzyme-based chemistries in order to detect glucose, glutamate, and choline by electrooxidation of the hydrogen peroxide produced in the reaction of the analytes with their corresponding oxidases. Problems concerning appropriate linear range, interference elimination, and cross-talk elimination were addressed. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 82
页数:8
相关论文
共 36 条
[1]   On-line coupling of microdialysis to packed capillary column liquid chromatography-tandem mass spectrometry demonstrated by measurement of free concentrations of ropivacaine and metabolite from spiked plasma samples [J].
Bergström, SK ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 775 (01) :79-87
[2]   A micromachined double lumen microdialysis probe connector with incorporated sensor for on-line sampling [J].
Böhm, S ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) :201-208
[3]  
Bowser MT, 2001, ELECTROPHORESIS, V22, P3668, DOI 10.1002/1522-2683(200109)22:17<3668::AID-ELPS3668>3.0.CO
[4]  
2-M
[5]   Ceramic-based multisite microelectrode array for rapid choline measures in brain tissue [J].
Burmeister, JJ ;
Palmer, M ;
Gerhardt, GA .
ANALYTICA CHIMICA ACTA, 2003, 481 (01) :65-74
[6]   In vivo on-line HPLC-microdialysis: simultaneous detection of monoamines and their metabolites in awake freely-moving rats [J].
Chaurasia, CS ;
Chen, CE ;
Ashby, CR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (3-4) :413-422
[7]  
Collins A, 2001, ELECTROANAL, V13, P425, DOI 10.1002/1521-4109(200104)13:6<425::AID-ELAN425>3.0.CO
[8]  
2-5
[9]   On-line glucose monitoring by using microdialysis sampling and amperometric detection based on 'wired' glucose oxidase in carbon paste [J].
Csoregi, E ;
Laurell, T ;
Katakis, I ;
Heller, A ;
Gorton, L .
MIKROCHIMICA ACTA, 1995, 121 (1-4) :31-40
[10]   Pharmacological evidence for the selectivity of in vivo signals obtained with enzyme-based electrochemical sensors [J].
Cui, J ;
Kulagina, NV ;
Michael, AC .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 104 (02) :183-189