Method development in high-performance liquid chromatography for high-throughput profiling and metabonomic studies of biofluid samples

被引:76
作者
Pham-Tuan, H [1 ]
Kaskavelis, L [1 ]
Daykin, CA [1 ]
Janssen, HG [1 ]
机构
[1] Unilever R&D Vlaardingen, Cent Analyt Sci Unit, NL-3130 AC Vlaardingen, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2003年 / 789卷 / 02期
关键词
high-throughput profiling; metabonomics; biological fluids; monolithic columns;
D O I
10.1016/S1570-0232(03)00077-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Metabonomics has in the past decade demonstrated enormous potential in furthering the understanding of, for example, disease processes, toxicological mechanisms, and biomarker discovery. The same principles can also provide a systematic and comprehensive approach to the study of food ingredient impact on consumer health. However, "metabonomic" methodology requires the development of rapid, advanced analytical tools to comprehensively profile biofluid metabolites within consumers. Until now, NMR spectroscopy has been used for this purpose almost exclusively. Chromatographic techniques and in particular HPLC, have not been exploited accordingly. The main drawbacks of chromatography are the long analysis time, instabilities in the sample fingerprint and the rigorous sample preparation required. This contribution addresses these problems in the quest to develop generic methods for high-throughput profiling using HPLC. After a careful optimization process, stable fingerprints of biofluid samples can be obtained using standard HPLC equipment. A method using a short monolithic column and a rapid gradient with a high flow-rate has been developed that allowed rapid and detailed profiling of larger numbers of urine samples. The method can be easily translated into a slow, shallow-gradient high-re solution method for identification of interesting peaks by LC-MS/NMR. A similar approach has been applied for cell culture media samples. Due to the much higher protein content of such samples non-porous polymer-based small particle columns yielded the best results. The study clearly shows that HPLC can be used in metabonomic fingerprinting studies. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:283 / 301
页数:19
相关论文
共 27 条
[1]  
Alam TM, 2001, SPECTROSCOPY, V16, P18
[2]   Rapid peptide mapping by reversed-phase liquid chromatography on nonporous silica with on-line electrospray time of flight mass spectrometry [J].
Banks, JF ;
Gulcicek, EE .
ANALYTICAL CHEMISTRY, 1997, 69 (19) :3973-3978
[3]   Chromatographic alignment by warping and dynamic programming as a pre-processing tool for PARAFAC modelling of liquid chromatography-mass spectrometry data [J].
Bylund, D ;
Danielsson, R ;
Malmquist, G ;
Markides, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (02) :237-244
[4]   Combined HPLC-MS and HPLC-NMR on-line coupling for the separation and determination of lutein and zeaxanthin stereoisomers in spinach and in retina [J].
Dachtler, M ;
Glaser, T ;
Kohler, K ;
Albert, K .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :667-674
[5]   The comparison of plasma deproteinization methods for the detection of low-molecular-weight metabolites by 1H nuclear magnetic resonance spectroscopy [J].
Daykin, CA ;
Foxall, PJD ;
Connor, SC ;
Lindon, JC ;
Nicholson, JK .
ANALYTICAL BIOCHEMISTRY, 2002, 304 (02) :220-230
[6]  
ERIKSSON L, 1999, UMETRICS
[7]   Metabolite profiling by one- and two-dimensional NMR analysis of complex mixtures [J].
Fan, WMT .
PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 1996, 28 (pt 2) :161-219
[8]  
GARTLAND KPR, 1991, MOL PHARMACOL, V39, P629
[9]   A high capacity LC/MS system for the bioanalysis of samples generated from plate-based metabolic screening [J].
Janiszewski, JS ;
Rogers, KJ ;
Whalen, KM ;
Cole, MJ ;
Liston, TE ;
Duchoslav, E ;
Fouda, HG .
ANALYTICAL CHEMISTRY, 2001, 73 (07) :1495-1501
[10]   Increased throughput in quantitative bioanalysis using parallel-column liquid chromatography with mass spectrometric detection [J].
Jemal, M ;
Huang, M ;
Mao, Y ;
Whigan, D ;
Powell, ML .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) :994-999