Sequential determination of Se(IV) and Se(VI) by flow injection-hydride generation-atomic absorption spectrometry with HCl/HBr microwave aided pre-reduction of Se(VI) to Se(IV)

被引:43
作者
Gallignani, M [1 ]
Valero, M [1 ]
Brunetto, MR [1 ]
Burguera, JL [1 ]
Burguera, M [1 ]
de Peña, YP [1 ]
机构
[1] Univ Los Andes, Fac Sci, Venezuelan Andean Inst Chem Res, Merida 5101 A, Venezuela
关键词
selenium; Se(IV); Se(VI); sequential determination; hydride generation; atomic absorption spectrometry; on-line flow injection;
D O I
10.1016/S0039-9140(00)00438-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study a flow injection (FI) system used in conjunction with hydride generation (HG), atomic absorption spectrometry (AAS) and microwave (MW) aided pre-reduction of selenite (Se(IV)) to selenate (Se(IV)) with HCl:HBr has been developed in order to differentiate both inorganic selenium species. As full control of the MW reduction step is possible, the experimental approach allows the use of milder acidic conditions (10% v/v of HCl and HBr) than those conventionally accomplished with hydrochloric acid alone (greater than or equal to 50% v/v). Experimental parameters were optimized by the univariate optimization method. Tn either case, the linear range was from 1.0 to 30 mug 1(-1). The detection limits based on 30 of the blank signal were 0.25 mug 1(-1) for Se(IV) and 0.30 mug 1(-1) for Se(VI). The reproducibility, about 3% RSD and recoveries of different amounts of Se(VI) and Se(IV) added to water and orange juice samples (97-103%) were good. The main advantage of the proposed method is that the sequential determination of Se(IV) and Se(VI) is performed at a high sampling frequency (ca. 50 samples per h) in a closed system without Se losses, and with a minimum sample waste, operator attention, and sample manipulation. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1015 / 1024
页数:10
相关论文
共 33 条
[12]  
CAISOT C, 1999, J ANAL ATMOS SPECTRO, V14, P645
[13]   SELECTIVE DETERMINATION OF ARSENIC (III, V), ANTIMONY (III, V), SELENIUM (IV, VI) AND TELLURIUM (IV, VI) BY EXTRACTION AND GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
CHUNG, CH ;
IWAMOTO, E ;
YAMAMOTO, M ;
YAMAMOTO, Y .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (2-3) :459-466
[14]  
COBO MG, 1993, ANAL CHIM ACTA, V283, P386
[15]   ON LINE SPECIATION OF SE(VI), SE(IV), AND TRIMETHYLSELENIUM BY HPLC MICROWAVE-OVEN HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
COBOFERNANDEZ, MG ;
PALACIOS, MA ;
CHAKRABORTI, D ;
QUEVAUILLER, P ;
CAMARA, C .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5) :438-442
[16]  
DEDINA J, 1995, HYDRIDE GENERATION A, P314
[17]   INDEXES OF SELENIUM STATUS IN HUMAN-POPULATIONS [J].
DIPLOCK, AT .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (02) :256-258
[19]   Selenium in health and disease: A review [J].
Foster, LH ;
Sumar, S .
CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 1997, 37 (03) :211-228
[20]  
Frost D V, 1972, CRC Crit Rev Toxicol, V1, P467