Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging

被引:182
作者
Alfakih, K
Plein, S
Bloomer, T
Jones, T
Ridgway, J
Sivananthan, M
机构
[1] Leeds Gen Infirm, BHF Cardiac MR Unit, Leeds LS1 3EX, W Yorkshire, England
[2] Leeds Gen Infirm, Dept Phys Med, Leeds LS1 3EX, W Yorkshire, England
关键词
magnetic resonance imaging; heart; steady-state imaging; right ventricular volumes; observer variability;
D O I
10.1002/jmri.10329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare right ventricular (RV) volume measurements and their, reproducibility between axial and short axis orientation acquisition-techniques. Materials and Methods: Measurements of RV volumes from data sets acquired in axial and short axis orientations were compared in 20 normal subjects: The observer variabilities were assessed and the deft ventricle (LV) and RV stroke volumes (SV) were,compared. Results: There was a significant and systematic difference in the EDV and ESV volumes between the axial and short axis methods. The latter method resulted in larger volumes (mean bias EDV 7.5 +/- 13.2, 4.7% difference, ESV 7.2 +/- 8.6, 10.7% difference). The axial method had lower intra- and, interobserver variability than: the short axis method. The standard deviation of the difference (SDD) and the limits of agreement were consistently lower for the axial method. The mean differences between LV and RV stroke volumes expressed as mean +/- SD (r(2) =correlation coefficient) were axial 7.6 +/- 9.1 (r(2) +/- 0.93); and short axis 7.4 +/- 10.8 (r(2) = 0.90). Conclusion: There is,a significant systematic difference. between volumes measured using the two different orientations. The axial orientation resulted in better inter- and intraobserver reproducibility.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 22 条
  • [11] Pulmonary valve insertion late after repair of Fallot's tetralogy
    Hazekamp, MG
    Kurvers, MMJ
    Schoof, PH
    Vliegen, HW
    Mulder, BM
    Roest, AAW
    Ottenkamp, J
    Dion, RAE
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 19 (05) : 667 - 670
  • [12] QUANTIFICATION OF RIGHT-VENTRICULAR FUNCTION WITH MAGNETIC-RESONANCE-IMAGING IN CHILDREN WITH NORMAL HEARTS AND WITH CONGENITAL HEART-DISEASE
    HELBING, WA
    REBERGEN, SA
    MALIEPAARD, C
    HANSEN, B
    OTTENKAMP, J
    REIBER, JHC
    DEROOS, A
    [J]. AMERICAN HEART JOURNAL, 1995, 130 (04) : 828 - 837
  • [13] COMPARISON OF ECHOCARDIOGRAPHIC METHODS WITH MAGNETIC-RESONANCE-IMAGING FOR ASSESSMENT OF RIGHT-VENTRICULAR FUNCTION IN CHILDREN
    HELBING, WA
    BOSCH, HG
    MALIEPAARD, C
    REBERGEN, SA
    VANDERGEEST, RJ
    HANSEN, B
    OTTENKAMP, J
    REIBER, JHC
    DEROOS, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (08) : 589 - 594
  • [14] ESTIMATION OF RIGHT VENTRICULAR MASS IN NORMAL SUBJECTS AND IN PATIENTS WITH PRIMARY PULMONARY-HYPERTENSION BY NUCLEAR-MAGNETIC-RESONANCE IMAGING
    KATZ, J
    WHANG, J
    BOXT, LM
    BARST, RJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (06) : 1475 - 1481
  • [15] Diagnosis of arrhythmogenic right ventricular dysplasia: A review
    Kayser, HWM
    van der Wall, EE
    Sivananthan, MU
    Plein, S
    Bloomer, TN
    de Roos, A
    [J]. RADIOGRAPHICS, 2002, 22 (03) : 639 - 648
  • [16] RIGHT-VENTRICULAR PERFORMANCE AND MASS BY USE OF CINE MRI LATE AFTER ATRIAL REPAIR OF TRANSPOSITION OF THE GREAT-ARTERIES
    LORENZ, CH
    WALKER, ES
    GRAHAM, TP
    POWERS, TA
    [J]. CIRCULATION, 1995, 92 (09) : 233 - 239
  • [17] MEE RBB, 1986, J THORAC CARDIOV SUR, V92, P385
  • [18] Moulton MJ, 1996, CIRCULATION, V94, P312
  • [19] REPRODUCIBILITY OF MRI-DERIVED MEASUREMENTS OF RIGHT-VENTRICULAR VOLUMES AND MYOCARDIAL MASS
    PATTYNAMA, PMT
    LAMB, HJ
    VANDERVELDE, EA
    VANDERGEEST, RJ
    VANDERWALL, EE
    DEROOS, A
    [J]. MAGNETIC RESONANCE IMAGING, 1995, 13 (01) : 53 - 63
  • [20] Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented K-space gradient-echo imaging
    Plein, S
    Bloomer, TN
    Ridgway, JP
    Jones, TR
    Bainbridge, GJ
    Sivananthan, MU
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (03) : 230 - 236