Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented K-space gradient-echo imaging

被引:178
作者
Plein, S [1 ]
Bloomer, TN [1 ]
Ridgway, JP [1 ]
Jones, TR [1 ]
Bainbridge, GJ [1 ]
Sivananthan, MU [1 ]
机构
[1] Gen Infirm, Cardiac Magnet Resonance Unit, Leeds LS1 3EX, W Yorkshire, England
关键词
magnetic resonance imaging; heart; steady-state imaging; gradient-echo imaging; volumes; automatic contour detection; variability;
D O I
10.1002/jmri.1178
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Steady-state free precession imaging is a promising technique for cardiac magnetic resonance imaging (MRI), as it provides improved blood/myocardial contrast in shorter acquisition times compared with conventional gradient-echo acquisition. The better contrast could improve observer agreement and automatic detection of cardiac contours for volumetric assessment of the ventricles, but measurements might differ from those obtained using conventional methods. We compared volumetric measurements, observer variabilities, and automatic contour detection between a steady-state free precession imaging sequence (BFFE = balanced fast field echo) and segmented k-space gradient-echo acquisition (TFE = turbo field echo) in 41 subjects. With BFFE, significantly higher end-diastolic and end-systolic volumes and lower wall thickness, ventricular mass, ejection fraction, and mall motion were observed (P < 0.0001), while interobserver variabilities were lower and automatic contour detection of endocardial contours was more successful. We conclude that the improved image quality of BFFE reduces the observer-dependence of volumetric measurements of the left ventricle (L but results in significantly different values in comparison to TFE measurements. J. Magn. Reson. Imaging 2001; 14:230-236. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:230 / 236
页数:7
相关论文
共 23 条
  • [1] MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study
    Barkhausen, J
    Ruehm, SG
    Goyen, M
    Buck, T
    Laub, G
    Debatin, JF
    [J]. RADIOLOGY, 2001, 219 (01) : 264 - 269
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] BUSER PT, 1989, J AM COLL CARDIOL, V6, P1924
  • [4] Reproducibility study of left ventricular measurements with breath-hold cine MRI using a semiautomated volumetric image analysis program
    Butler, SP
    McKay, E
    Paszkowski, AL
    Quinn, RJ
    Shnier, RC
    Donovan, JT
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 467 - 472
  • [5] LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY
    CRANNEY, GB
    LOTAN, CS
    DEAN, L
    BAXLEY, W
    BOUCHARD, A
    POHOST, GM
    [J]. CIRCULATION, 1990, 82 (01) : 154 - 163
  • [6] Deimling M., 1994, PROC 2 ANN M SMR SAN, P495
  • [7] FANG W, 2000, P 8 ANN M ISMRM DENV, P308
  • [8] MEASUREMENT OF LEFT-VENTRICULAR MASS INVIVO USING GATED NUCLEAR-MAGNETIC-RESONANCE IMAGING
    FLORENTINE, MS
    GROSSKREUTZ, CL
    CHANG, W
    HARTNETT, JA
    DUNN, VD
    EHRHARDT, JC
    FLEAGLE, SR
    COLLINS, SM
    MARCUS, ML
    SKORTON, DJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 8 (01) : 107 - 112
  • [9] STEADY-STATE FREE PRECESSION IMAGING IN THE PRESENCE OF MOTION - APPLICATION FOR IMPROVED VISUALIZATION OF THE CEREBROSPINAL-FLUID
    HAACKE, EM
    WIELOPOLSKI, PA
    TKACH, JA
    MODIC, MT
    [J]. RADIOLOGY, 1990, 175 (02) : 545 - 552
  • [10] FAST MR-IMAGING - TECHNIQUES AND CLINICAL-APPLICATIONS
    HAACKE, EM
    TKACH, JA