Accuracy of the EasyTouch blood glucose self-monitoring system: a study of 516 cases

被引:24
作者
Dai, KS
Tai, DY
Ho, P
Chen, CC
Peng, WC
Chen, ST
Hsu, CC
Liu, YP
Hsieh, HC
Yang, CC
Tsai, MC
Mao, SJT
机构
[1] Bioptik Technol Inc, Hsinchu 300, Taiwan
[2] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu, Taiwan
[3] Wei Gong Mem Hosp, Miaoli, Taiwan
[4] Taipei Med Univ, Sch Med Technol, Taipei, Taiwan
关键词
diabetes mellitus; glucose self-monitoring system; Clarke Error Grid analysis; home testing; point-of-care testing;
D O I
10.1016/j.cccn.2004.06.010
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Self-monitoring blood glucose device is an important toot for diabetes patients to efficiently control their blood glucose concentrations. We evaluated the accuracy of EasyTouch glucose monitoring system. Methods: Capillary blood glucose concentrations measured using EasyTouch and the reference values obtained from Yellow Springs Instruments (YSI) 2300 STAT were performed in the Department of Laboratory Medicine, Wei-Gong Memorial Hospital. Results were evaluated using (1) linear regression analysis, (2) Clarke Error Grid analysis, (3) percentage of readings within a defined range of deviation from the reference value, (4) bias plots, and (5) coefficients of variation (CVs) calculated from 60 measurements in series. Results: The window of the 516 EasyTouch readings covered a range from 42 to 555 mg/dl. Linear regression analysis yielded a regression slope 0.9972, intercept 1.899 mg/dl, r(2) 0.9571, and Syx 14.89 mg/dl. A Clarke Error Grid analysis showed 100% of the EasyTouch readings in clinically acceptable zones A and B. Of the EasyTouch readings, 98.3%, 91.9%, 78.3% and 46.9% were found within +/-20%, +/-15%, +/-10%, and +/-5%, respectively, of the reference values. Further analysis showed that the percentage of EasyTouch readings within the defined intervals was similar in three glucose ranges (less than or equal to100, 101-200, and greater than or equal to201 mg/dl). The CVs for the four lots of strips (lot 1 to lot 4) ranged from 3.5 to 5.5%, 2.1 to 4.8%, 1.8 to 3.6%, and 3.0 to 5.7%, respectively. Conclusions: EasyTouch provides high accurate and precise glucose readings over a wide range of glucose concentrations. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 26 条
[11]   SELF-MONITORING OF BLOOD-GLUCOSE, AS A MEANS OF SELF-MANAGEMENT [J].
IKEDA, Y ;
TSURUOKA, A .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1994, 24 :S269-S271
[12]  
*ISO CD, 2001, 15197 ISOCD
[13]  
Jones BA, 1996, ARCH PATHOL LAB MED, V120, P339
[14]   A WARD COMPARISON BETWEEN THE ONE TOUCH-II AND GLUCOMETER-II BLOOD-GLUCOSE METERS [J].
KILPATRICK, ES ;
MCLEOD, MJ ;
RUMLEY, AG ;
SMALL, M .
DIABETIC MEDICINE, 1994, 11 (02) :214-217
[15]  
Novis DA, 1998, ARCH PATHOL LAB MED, V122, P495
[16]  
Petersen M, 2003, DIABETES CARE, V26, P917
[17]   Clinical and statistical evaluation of self-monitoring blood glucose meters [J].
Poirier, JY ;
Le Prieur, N ;
Campion, L ;
Guilhem, I ;
Allannic, H ;
Maugendre, D .
DIABETES CARE, 1998, 21 (11) :1919-1924
[18]  
Rheney CC, 2000, ANN PHARMACOTHER, V34, P317
[19]  
Sacks DB, 2002, CLIN CHEM, V48, P436
[20]   THE EFFECT OF INTENSIVE TREATMENT OF DIABETES ON THE DEVELOPMENT AND PROGRESSION OF LONG-TERM COMPLICATIONS IN INSULIN-DEPENDENT DIABETES-MELLITUS [J].
SHAMOON, H ;
DUFFY, H ;
FLEISCHER, N ;
ENGEL, S ;
SAENGER, P ;
STRELZYN, M ;
LITWAK, M ;
WYLIEROSETT, J ;
FARKASH, A ;
GEIGER, D ;
ENGEL, H ;
FLEISCHMAN, J ;
POMPI, D ;
GINSBERG, N ;
GLOVER, M ;
BRISMAN, M ;
WALKER, E ;
THOMASHUNIS, A ;
GONZALEZ, J ;
GENUTH, S ;
BROWN, E ;
DAHMS, W ;
PUGSLEY, P ;
MAYER, L ;
KERR, D ;
LANDAU, B ;
SINGERMAN, L ;
RICE, T ;
NOVAK, M ;
SMITHBREWER, S ;
MCCONNELL, J ;
DROTAR, D ;
WOODS, D ;
KATIRGI, B ;
LITVENE, M ;
BROWN, C ;
LUSK, M ;
CAMPBELL, R ;
LACKAYE, M ;
RICHARDSON, M ;
LEVY, B ;
CHANG, S ;
HEINHEINEMANN, M ;
BARRON, S ;
ASTOR, L ;
LEBECK, D ;
BRILLON, D ;
DIAMOND, B ;
VASILASDWOSKIN, A ;
LAURENZI, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :977-986