Pre-analytical phase management: a review of the procedures from patient preparation to laboratory analysis

被引:53
作者
Lima-Oliveira, Gabriel [1 ,2 ]
Volanski, Waldemar [1 ]
Lippi, Giuseppe [2 ]
Picheth, Geraldo [1 ]
Guidi, Gian Cesare [1 ,2 ]
机构
[1] Univ Fed Parana, Dept Clin Anal, Postgrad Program Pharmaceut Sci, Curitiba, Parana, Brazil
[2] Univ Verona, Lab Clin Biochem, Dept Neurosci Biomed & Movement Sci, Verona, Italy
关键词
Blood specimen collection; clinical laboratory techniques; patient safety; quality control; total quality management; VACUUM TUBES VALIDATION; TEST-REQUEST MANAGEMENT; TERM VENOUS STASIS; CLINICAL-CHEMISTRY; BLOOD COLLECTION; PNEUMATIC TUBE; ACID EDTA; AUTOMATED TRANSPORT; ROUTINE HEMATOLOGY; DIAGNOSTIC ERROR;
D O I
10.1080/00365513.2017.1295317
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The pre-analytical phase encompasses all the procedures before the start of laboratory testing. This phase of the testing process is responsible for the majority of the laboratory errors, since the related procedures involve many sorts of non-laboratory professionals working outside the laboratory setting, thus without direct supervision by the laboratory staff. Therefore, either correct organization or management of both personnel and procedures that regard blood specimen collection by venipuncture are of fundamental importance, since the various steps for performing blood collection represent per se sources of laboratory variability. The aim of this (non-systematic) review addressed to healthcare professionals is to highlight the importance of blood specimen management (from patient preparation to laboratory analyses), as a tool to prevent laboratory errors, with the concept that laboratory results from inappropriate blood specimens are inconsistent and do not allow proper treatment nor monitoring of the patient.
引用
收藏
页码:153 / 163
页数:11
相关论文
共 98 条
[61]   New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry [J].
Lima-Oliveira, Gabriel ;
Lippi, Giuseppe ;
Salvagno, Gian Luca ;
Montagnana, Martina ;
Pitangueira Manguera, Cristovao Luis ;
Sumita, Nairo M. ;
Picheth, Geraldo ;
Guidi, Gian Cesare ;
Scartezini, Marileia .
BIOCHEMIA MEDICA, 2011, 21 (02) :152-159
[62]   Venous stasis and routine hematologic testing [J].
Lippi, G. ;
Salvagno, G. L. ;
Montagnana, M. ;
Franchini, M. ;
Guidi, G. C. .
CLINICAL AND LABORATORY HAEMATOLOGY, 2006, 28 (05) :332-337
[63]   Short-term venous stasis influences routine coagulation testing [J].
Lippi, G ;
Salvagno, GL ;
Montagnana, M ;
Guidi, GC .
BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 (06) :453-458
[64]   Influence of short-term venous stasis on clinical chemistry testing [J].
Lippi, G ;
Salvagno, GL ;
Montagnana, M ;
Brocco, G ;
Guidi, GC .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (08) :869-875
[65]   Influence of the needle bore size used for collecting venous blood samples on routine clinical chemistry testing [J].
Lippi, Giuseppe ;
Salvagno, Gian Luca ;
Montagnana, Martina ;
Brocco, Giorgio ;
Guidi, Gian Cesare .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (08) :1009-1014
[66]   EFLM WG-Preanalytical phase opinion paper: local validation of blood collection tubes in clinical laboratories [J].
Lippi, Giuseppe ;
Cornes, Michael P. ;
Grankvist, Kjell ;
Nybo, Mads ;
Simundic, Ana-Maria .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (05) :755-760
[67]   Does fist pumping/clenching during venipuncture activate blood coagulation? [J].
Lippi, Giuseppe ;
Lima-Oliveira, Gabriel ;
Guidi, Gian Cesare .
BLOOD COAGULATION & FIBRINOLYSIS, 2016, 27 (03) :357-358
[68]   Influence of posture on routine hemostasis testing [J].
Lippi, Giuseppe ;
Salvagno, Gian Luca ;
Lima-Oliveira, Gabriel ;
Danese, Elisa ;
Favaloro, Emmanuel J. ;
Guidi, Gian Cesare .
BLOOD COAGULATION & FIBRINOLYSIS, 2015, 26 (06) :716-719
[69]   Postural change during venous blood collection is a major source of bias in clinical chemistry testing [J].
Lippi, Giuseppe ;
Salvagno, Gian Luca ;
Lima-Oliveira, Gabriel ;
Bracco, Giorgio ;
Danese, Elisa ;
Guidi, Gian Cesare .
CLINICA CHIMICA ACTA, 2015, 440 :164-168
[70]   Circulating cardiac troponin T is not influenced by postural changes during venous blood collection [J].
Lippi, Giuseppe ;
Salvagno, Gian Luca ;
Lima-Oliveira, Gabriel ;
Montagnana, Martina ;
Danese, Elisa ;
Guidi, Gian Cesare .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (03) :1076-1077