Microconcentric nebuliser for the analysis of small sample volumes by inductively coupled plasma mass spectrometry

被引:24
作者
Lofthouse, SD
Greenway, GM
Stephen, SC
机构
[1] Univ Hull, Hull HU6 7RX, N Humberside, England
[2] Zeneca Special, Manchester M9 8ZS, Lancs, England
关键词
microconcentric nebuliser; inductively coupled plasma mass spectrometry; small volume samples; biological samples;
D O I
10.1039/a705047j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microconcentric nebuliser was evaluated for the analysis of small volumes of sample. An optimum set of conditions was obtained for a range of analytes by optimisation of the nebuliser gas flow rate. The technique was evaluated by accurate analysis of reference material NIES No. 5 using just 100 mu l of sample. Recoveries between 95 and 106% were obtained for all the elements determined. The technique was then applied to the analysis of biological samples and to the analysis of a peptide, with multi-element analysis on less than 100 mu l of sample. Acceptable reproducibility and precision were obtained for both sample types. Recoveries between 95 and 118% were obtained for the biological samples and between 72 and 104% for the peptide samples. The microconcentric nebuliser permits a significant decrease in sample volume for multi-element analysis without loss of accuracy.
引用
收藏
页码:1373 / 1376
页数:4
相关论文
共 12 条
[1]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[2]   Determination of copper, cadmium and lead in biological samples by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry [J].
Chang, CC ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (01) :75-80
[3]   Determination of gold and platinum in the presence of blood plasma proteins using inductively coupled plasma mass spectrometry with direct injection nebulization [J].
Christodoulou, J ;
Kashani, M ;
Keohane, BM ;
Sadler, PJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (11) :1031-1035
[4]   Waste reduction in inductively coupled plasma mass spectrometry using flow injection and a direct injection nebulizer [J].
Crain, JS ;
Kiely, JT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :525-527
[5]   THE ROLE OF CHEMICAL MODIFIERS IN ANALYTE TRANSPORT LOSS INTERFERENCES WITH ELECTROTHERMAL VAPORIZATION ICP-MASS SPECTROMETRY [J].
EDIGER, RD ;
BERES, SA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (07) :907-922
[6]   INTERPRETING SOME ANALYTICAL CHARACTERISTICS OF THERMAL DISPERSION METHODS USED FOR SAMPLE INTRODUCTION IN ATOMIC SPECTROMETRY [J].
KANTOR, T .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (9-11) :1299-1320
[7]   PARTICLE-SIZE DISTRIBUTION OF SAMPLE TRANSPORTED FROM AN ELECTROTHERMAL VAPORIZER TO AN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETER [J].
SPARKS, CM ;
HOLCOMBE, J ;
PINKSTON, TL .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (13) :1607-1615
[8]  
ULRICH A, 1992, ANAL PROC, V29, P284, DOI 10.1039/ap9922900284
[9]   Evaluation of a commercially available microconcentric nebulizer for inductively coupled plasma mass spectrometry [J].
Vanhaecke, F ;
VanHolderbeke, M ;
Moens, L ;
Dams, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (08) :543-548
[10]   DIRECT INJECTION NEBULIZATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
WIEDERIN, DR ;
SMITH, FG ;
HOUK, RS .
ANALYTICAL CHEMISTRY, 1991, 63 (03) :219-225