High conformality radiotherapy in Europe: thirty-one centres participating in the quality assurance programme of the EORTC prostate trial 22991

被引:11
作者
Ataman, F
Poortmans, P
Davis, JB
Bernier, J
Giraud, JY
Kouloulias, VE
Pierart, M
Bolla, M
机构
[1] Eortc Data Ctr, Radiotherapy Grp, B-1200 Brussels, Belgium
[2] Dr Bernard Verbeeten Inst, Dept Radiotherapy, NL-5042 SB Tilburg, Netherlands
[3] Univ Zurich Hosp, Dept Radiat Oncol, CH-8091 Zurich, Switzerland
[4] Osped San Giovanni Bellinzona, Dept Radiotherapy, CH-6500 Bellinzona, Switzerland
[5] CHU Grenoble, Dept Radiotherapy, F-38043 Grenoble, France
[6] Aret Univ, Dept Radiotherapy, Athens 11528, Greece
关键词
quality assurance; questionnaire; EORTC; prostate cancer; conformal radiotherapy;
D O I
10.1016/j.ejca.2004.07.019
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Today, conformality in radiotherapy is at the centre of many investments in equipment and staffing. To estimate the current situation within the European Organisation for Research and Treatment of Cancer (EORTC) conformal radiotherapy trial for prostate cancer, a technology questionnaire was designed to assess whether participating centres can comply with the required radiotherapy procedures of EORTC trial 22991, where a high dose is prescribed to the prostate. Questions covered various items of computed tomography, data acquisition, treatment planning, delivery and verification. All centres (n = 31) replied to the questionnaire. All generate beam's eye views and dose volume histograms. All, but two, centres use digitally reconstructed radiographs to display images. The vast majority of the centres perform at least weekly treatment verification and half have access to individual in vivo dosimetry. The results of the questionnaire indicate that participating centres have access to the equipment and apply the procedures that are essential for conformal prostate radiotherapy. The technology questionnaire is the first step in the extensive quality assurance programme dedicated to this high-tech radiotherapy trial. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2411 / 2416
页数:6
相关论文
共 23 条
[1]
THE EFFECTIVENESS OF IMMOBILIZATION DURING PROSTATE IRRADIATION [J].
BENTEL, GC ;
MARKS, LB ;
SHEROUSE, GW ;
SPENCER, DP ;
ANSCHER, MS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01) :143-148
[2]
Dose escalation with 3D-CRT in prostate cancer: French study of dose escalation with conformal 3D radiotherapy in prostate cancer - Preliminary results [J].
Bey, P ;
Carrie, C ;
Beckendorf, V ;
Ginestet, C ;
Aletti, P ;
Madelis, G ;
Luporsi, E ;
Pommier, P ;
Cowen, D ;
Gonzague-Casabianca, L ;
Simonian-Sauve, M ;
Maingon, P ;
Naudy, S ;
Lagrange, JL ;
Marcie, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :513-517
[3]
Reproducibility of conformal radiation therapy in localized carcinoma of the prostate without rigid immobilization [J].
Bieri, S ;
Miralbell, R ;
Nouet, P ;
Delorme, H ;
Rouzaud, M .
RADIOTHERAPY AND ONCOLOGY, 1996, 38 (03) :223-230
[4]
BOLLA M, EORTC TRIAL 22991 3
[5]
TIME TREND OF PATIENT SETUP DEVIATIONS DURING PELVIC IRRADIATION USING ELECTRONIC PORTAL IMAGING [J].
ELGAYED, AAH ;
BEL, A ;
VIJLBRIEF, R ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 26 (02) :162-171
[6]
In vivo dosimetry during external photon beam radiotherapy [J].
Essers, M ;
Mijnheer, BJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (02) :245-259
[7]
THE USE OF DIGITALLY RECONSTRUCTED RADIOGRAPHS FOR 3-DIMENSIONAL TREATMENT PLANNING AND CT-SIMULATION [J].
GALVIN, JM ;
SIMS, C ;
DOMINIAK, G ;
COOPER, JS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (04) :935-942
[8]
Impact of tissues heterogeneities on monitor units calculation and ICRU dose point: Analysis of 30 cases of prostate cancer treated with 18-MV photons after three-dimensional planning [J].
Ginestet, C ;
Malet, C ;
Cohen, A ;
Lafay, F ;
Carrie, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (02) :529-534
[9]
Dose escalation with 3D conformal treatment: Five year outcomes, treatment optimization, and future directions [J].
Hanks, GE ;
Hanlon, AL ;
Schultheiss, TE ;
Pinover, WH ;
Movsas, B ;
Epstein, BE ;
Hunt, MA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (03) :501-510
[10]
*INT COMM RAD UN M, 62 ICRU INT COMM RAD