Blood coagulation screening using a paper-based microfluidic lateral flow device

被引:91
作者
Li, H. [1 ]
Han, D. [1 ]
Pauletti, G. M. [2 ]
Steckl, A. J. [1 ]
机构
[1] Univ Cincinnati, Coll Engn & Appl Sci, Dept Elect Engn & Comp Syst, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, James L Winkle Coll Pharm, Cincinnati, OH 45221 USA
基金
美国国家科学基金会;
关键词
WHOLE-BLOOD; PLASMA; POINT;
D O I
10.1039/c4lc00716f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple approach to the evaluation of blood coagulation using a microfluidic paper-based lateral flow assay (LEA) device for point-of-care (POC) and self-monitoring screening is reported. The device utilizes whole blood, without the need for prior separation of plasma from red blood cells (RBC). Experiments were performed using animal (rabbit) blood treated with trisodium citrate to prevent coagulation. CaCl2 solutions of varying concentrations are added to citrated blood, producing Ca2+ ions to re-establish the coagulation cascade and mimic different blood coagulation abilities in vitro. Blood samples are dispensed into a paper-based LFA device consisting of sample pad, analytical membrane and wicking pad. The porous nature of the cellulose membrane separates the aqueous plasma component from the large blood cells. Since the viscosity of blood changes with its coagulation ability, the distance RBCs travel in the membrane in a given time can be related to the blood clotting time. The distance of the RBC front is found to decrease linearly with increasing CaCl2 concentration, with a travel rate decreasing from 3.25 mm min(-1) for no added CaCl2 to 2.2 mm min(-1) for 500 mM solution. Compared to conventional plasma clotting analyzers, the LFA device is much simpler and it provides a significantly larger linear range of measurement. Using the red colour of RBCs as a visible marker, this approach can be utilized to produce a simple and clear indicator of whether the blood condition is within the appropriate range for the patient's condition.
引用
收藏
页码:4035 / 4041
页数:7
相关论文
共 38 条
[31]   CIRCUITS ON CELLULOSE [J].
Steckl, Andrew J. .
IEEE SPECTRUM, 2013, 50 (02) :48-+
[32]  
Tabeling P., 2005, INTRO MICROFLUIDICS
[33]   Paper Electronics [J].
Tobjork, Daniel ;
Osterbacka, Ronald .
ADVANCED MATERIALS, 2011, 23 (17) :1935-1961
[34]   Blood-on-a-chip [J].
Toner, M ;
Irimia, D .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2005, 7 :77-103
[35]   The dynamics of capillary flow. [J].
Washburn, EW .
PHYSICAL REVIEW, 1921, 17 (03) :273-283
[36]   Integrated separation of blood plasma from whole blood for microfluidic paper-based analytical devices [J].
Yang, Xiaoxi ;
Forouzan, Omid ;
Brown, Theodore P. ;
Shevkoplyas, Sergey S. .
LAB ON A CHIP, 2012, 12 (02) :274-280
[37]   Paper-based microfluidic point-of-care diagnostic devices [J].
Yetisen, Ali Kemal ;
Akram, Muhammad Safwan ;
Lowe, Christopher R. .
LAB ON A CHIP, 2013, 13 (12) :2210-2251
[38]   Micromagnetic-microfluidic blood cleansing device [J].
Yung, Chong Wing ;
Fiering, Jason ;
Mueller, Andrew J. ;
Ingber, Donald E. .
LAB ON A CHIP, 2009, 9 (09) :1171-1177