Probability of failure of the watershed algorithm for peak detection in comprehensive two-dimensional chromatography

被引:26
作者
Vivo-Truyols, Gabriel [1 ]
Janssen, Hans-Gerd [1 ,2 ]
机构
[1] Univ Amsterdam, Analyt Chem Grp, vant Hoff Inst Mol Sci, NL-1018 WV Amsterdam, Netherlands
[2] Unilever Res Labs, Adv Measurement & Data Modelling, NL-3130 AC Vlaardingen, Netherlands
关键词
Two-dimensional chromatography; Watershed algorithm; Peak detection; LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; QUANTIFICATION; PROTEOMICS;
D O I
10.1016/j.chroma.2009.12.063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The watershed algorithm is the most common method used for peak detection and integration In two-dimensional chromatography However, the retention time variability in the second dimension may render the algorithm to fail A study calculating the probabilities of failure of the watershed algorithm was performed The main objective was to calculate the maximum second-dimension retention dine variability. Delta(2)t(Rcut). above which the algorithm fails Several models to calculate Delta(2)t(Rcut) were developed and evaluated (a) exact model. (b) simplified model and (c) simple-modified model Model (c) gave Isle best performance anti allowed to deduce an analytical expression for the probability of failure of the water shed algorithm as a function of experiment al Delta(2)t(R). modulation time anti peak width in the first and second dimensions It could be demonstrated that The probability of failure of the watershed algorithm under normal conditions in GC x GC Is around 15-20% Small changes of Delta(2)t(R), modulation time and/or peak width in the first anti second dimension could Induce subtle changes in the probability of failure of the watershed algorithm Theoretical equations were verified with experimental results from a diesel sample injected in GC x GC and were found to be ill good agreement with the experiments (C) 2009 Elsevier 13 V All I fights reserved
引用
收藏
页码:1375 / 1385
页数:11
相关论文
共 14 条
[1]   Quantification in comprehensive two-dimensional gas chromatography and a model of quantification based on selected summed modulated peaks [J].
Amador-Munoz, Omar ;
Marriott, Philip J. .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :323-340
[2]  
Beens J, 1998, HRC-J HIGH RES CHROM, V21, P47
[3]   Technical, bioinformatical and statistical aspects of liquid chromatography-mass spectrometry (LC-MS) and capillary electrophoresis-mass spectrometry (CE-MS) based clinical proteomics: A critical assessment [J].
Dakna, Mohammed ;
He, Zengyou ;
Yu, Wei Chuan ;
Mischak, Harald ;
Kolch, Walter .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (13) :1250-1258
[4]   Start-to-end processing of two-dimensional gel electrophoretic images [J].
Daszykowski, M. ;
Stanimirova, I. ;
Bodzon-Kulakowska, A. ;
Silberring, J. ;
Lubec, G. ;
Walczak, B. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1158 (1-2) :306-317
[5]  
FELINGER A, 1998, DATA ANAL SIGNAL PRO, pCH8
[6]   Comprehensive liquid chromatography: Fundamental aspects and practical considerations-A review [J].
Francois, Isabelle ;
Sandra, Koen ;
Sandra, Pat .
ANALYTICA CHIMICA ACTA, 2009, 641 (1-2) :14-31
[7]   Methods, algorithms and tools in computational proteomics: A practical point of view [J].
Matthiesen, Rune .
PROTEOMICS, 2007, 7 (16) :2815-2832
[8]   TOPOGRAPHIC DISTANCE AND WATERSHED LINES [J].
MEYER, F .
SIGNAL PROCESSING, 1994, 38 (01) :113-125
[9]   Quantification in comprehensive two-dimensional liquid chromatography [J].
Mondello, Luigi ;
Herrero, Miguel ;
Kumm, Tiina ;
Dugo, Paola ;
Cortes, Hernan ;
Dugo, Giovanni .
ANALYTICAL CHEMISTRY, 2008, 80 (14) :5418-5424
[10]   Development of an algorithm for peak detection in comprehensive two-dimensional chromatography [J].
Peters, Sonja ;
Vivo-Truyols, Gabriel ;
Marriott, Philip J. ;
Schoenmakers, Peter J. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1156 (1-2) :14-24