Amperometric detection of quantal catecholamine secretion from individual cells on micromachined silicon chips

被引:74
作者
Chen, P
Xu, B
Tokranova, N
Feng, XJ
Castracane, J
Gillis, KD
机构
[1] Univ Missouri, Dept Elect Engn, Columbia, MO 65211 USA
[2] Univ Missouri, Dept Biol Engn, Columbia, MO 65211 USA
[3] Univ Missouri, Dept Physiol, Columbia, MO 65211 USA
[4] Univ Missouri, Dalton Cardiovasc Res Ctr, Columbia, MO 65211 USA
[5] SUNY Albany, Sch Nanosci & Nanoengn, Albany, NY 12222 USA
关键词
D O I
10.1021/ac025802m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have fabricated electrochemical electrodes in picoliter-sized wells for measuring catecholamine release from individual cells with millisecond resolution. Each well-electrode roughly conforms to the shape of the cell in order to capture a large fraction of released catecholamine with high time resolution. Using this device, we can resolve spikes in amperometric current corresponding to quantal catecholamine release via exocytosis. In addition, we have combined amperometric recording on the chip with patch-clamp recordings of membrane capacitance as an assay of exocytosis. A quantitative comparison of the two methods suggests that a large fraction of catecholamine release is oxidized on the surface of the well-electrode. This technology has applications in cell-based biosensor development, high-throughput screening of drugs, and basic science investigations.
引用
收藏
页码:518 / 524
页数:7
相关论文
共 29 条
[11]  
F Allen J Bard L.R., 2001, Electrochemical Methods: Fundamentals and Applications
[12]   Whole cell patch clamp recording performed on a planar glass chip [J].
Fertig, N ;
Blick, RH ;
Behrends, JC .
BIOPHYSICAL JOURNAL, 2002, 82 (06) :3056-3062
[13]   Control of fusion pore dynamics during exocytosis by Munc18 [J].
Fisher, RJ ;
Pevsner, J ;
Burgoyne, RD .
SCIENCE, 2001, 291 (5505) :875-878
[14]   Admittance-based measurement of membrane capacitance using the EPC-9 patch-clamp amplifier [J].
Gillis, KD .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2000, 439 (05) :655-664
[15]  
Gillis Kevin D., 1995, P155
[16]  
JANKOWSKI JA, 1992, J BIOL CHEM, V267, P18329
[17]  
JANKOWSKI JA, 1993, J BIOL CHEM, V268, P14694
[18]   Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells [J].
Klemic, KG ;
Klemic, JF ;
Reed, MA ;
Sigworth, FJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :597-604
[19]   Estimation of mean exocytic vesicle capacitance in mouse adrenal chromaffin cells [J].
Moser, T ;
Neher, E .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1997, 94 (13) :6735-6740
[20]   COLOCALIZATION OF CALCIUM-ENTRY AND EXOCYTOTIC RELEASE SITES IN ADRENAL CHROMAFFIN CELLS [J].
ROBINSON, IM ;
FINNEGAN, JM ;
MONCK, JR ;
WIGHTMAN, RM ;
FERNANDEZ, JM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (07) :2474-2478