High resolution and small volume automatic ultrasonic velocimeter for liquids

被引:29
作者
Lautscham, K [1 ]
Wente, F [1 ]
Schrader, W [1 ]
Kaatze, U [1 ]
机构
[1] Univ Gottingen, Drittes Phys Inst, D-37073 Gottingen, Germany
关键词
sound velocity; adiabatic compressibility; ultrasonic resonator; process control; solvation properties;
D O I
10.1088/0957-0233/11/10/303
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A method is described to precisely measure the sound velocity of liquids. The construction of a resonator cell for the simultaneous measurement of a sample liquid and a reference liquid is presented. The non-ideal properties of the cavity resonators are carefully considered for a superior evaluation of the resonance frequency data Also presented is a low-priced electronic set-up, designed for the computer-controlled determination of the complex transfer functions of the cavity resonators and also for automatic temperature monitoring and control. Possible sources of errors are discussed and some representative results are presented in order to illustrate the repeatability of the method and the accuracy of the sound velocity data relative to a reference liquid.
引用
收藏
页码:1432 / 1439
页数:8
相关论文
共 22 条
[11]   Broad-band ultrasonic measurement techniques for liquids [J].
Eggers, F ;
Kaatze, U .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (01) :1-19
[12]   Cholesterol-induced variations in the volume and enthalpy fluctuations of lipid bilayers [J].
Halstenberg, S ;
Heimburg, T ;
Hianik, T ;
Kaatze, U ;
Krivanek, R .
BIOPHYSICAL JOURNAL, 1998, 75 (01) :264-271
[13]   Interaction of crystalline bacterial cell surface proteins with lipid bilayers in liposomes.: A sound velocity study [J].
Hianik, T ;
Küpcü, S ;
Sleytr, UB ;
Rybár, P ;
Krivánek, R ;
Kaatze, U .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1999, 147 (03) :331-339
[14]   ACOUSTICAL ABSORPTION-SPECTROSCOPY OF LIQUIDS BETWEEN 0.15 AND 3000 MHZ .1. HIGH-RESOLUTION ULTRASONIC RESONATOR METHOD [J].
KAATZE, U ;
WEHRMANN, B ;
POTTEL, R .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (08) :1025-1030
[15]  
Kononenko VS, 1997, ACOUST PHYS+, V43, P354
[16]  
KONONENKO VS, 1984, SOV PHYS ACOUST+, V30, P466
[17]   HIGH-RESOLUTION AND LOW VOLUME ULTRASONIC RESONATOR METHOD FOR FAST CHEMICAL RELAXATION MEASUREMENTS [J].
LABHARDT, A ;
SCHWARZ, G .
BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1976, 80 (01) :83-92
[18]  
RUPPRECHT A, 1997, THESIS
[19]   DEVELOPMENT OF METHODS OF PRECISE ULTRASONIC MEASUREMENTS IN SMALL VOLUMES OF LIQUIDS [J].
SARVAZYAN, AP .
ULTRASONICS, 1982, 20 (04) :151-154
[20]   FORCED BRILLOUIN SPECTROSCOPY USING FREQUENCY-TUNABLE CONTINUOUS-WAVE LASERS [J].
SONEHARA, T ;
TANAKA, H .
PHYSICAL REVIEW LETTERS, 1995, 75 (23) :4234-4237